Application of Disruptive Tests for the Determination of BIL through Spinterometric Spheres in the High Voltage Laboratory of the Salesian Polytechnic University

D. Criollo-Tacuri, S. Tapia-Cardenas, F. Quizhpi-Palomeque
{"title":"Application of Disruptive Tests for the Determination of BIL through Spinterometric Spheres in the High Voltage Laboratory of the Salesian Polytechnic University","authors":"D. Criollo-Tacuri, S. Tapia-Cardenas, F. Quizhpi-Palomeque","doi":"10.1109/CEIDP.2018.8544749","DOIUrl":null,"url":null,"abstract":"BIL is the basic level of insulation for lightning impulse test or NBI that determines the dielectric strength of a device which is expressed as a function of the peak value of a standard pulse. The research carried out contributes with values in disruptive tests in medium voltage devices through spinterometric spheres constructed, in their electronic stage, by the authors. which allow lightning-type discharge. This document presents the tests carried out at different voltage levels and determines the percentage of failure probability of the device. In this proposed approach, each of the devices will have its atmospheric correction factor for the positive and negative impulse tests, obtaining the parameters and adequate voltage levels for the applied tests. In this way the functioning of the proposed electronic circuit for the spheres was validated, the respective analysis of the tests was carried out according to the IEEE Std 4 applied for this type of tests.","PeriodicalId":377544,"journal":{"name":"2018 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2018.8544749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

BIL is the basic level of insulation for lightning impulse test or NBI that determines the dielectric strength of a device which is expressed as a function of the peak value of a standard pulse. The research carried out contributes with values in disruptive tests in medium voltage devices through spinterometric spheres constructed, in their electronic stage, by the authors. which allow lightning-type discharge. This document presents the tests carried out at different voltage levels and determines the percentage of failure probability of the device. In this proposed approach, each of the devices will have its atmospheric correction factor for the positive and negative impulse tests, obtaining the parameters and adequate voltage levels for the applied tests. In this way the functioning of the proposed electronic circuit for the spheres was validated, the respective analysis of the tests was carried out according to the IEEE Std 4 applied for this type of tests.
散射试验在慈利工大学高压实验室中测定BIL的应用
BIL是雷电脉冲试验或NBI的基本绝缘等级,它决定了设备的介电强度,其表示为标准脉冲峰值的函数。通过作者在其电子阶段构建的spinterometric球体,所进行的研究有助于在中压器件中进行破坏性试验的值。允许雷电型放电。本文档介绍了在不同电压水平下进行的测试,并确定了设备故障概率的百分比。在这种建议的方法中,每个设备都将具有其用于正脉冲和负脉冲试验的大气校正因子,从而获得应用试验的参数和适当的电压水平。通过这种方式,验证了拟议的球体电子电路的功能,并根据适用于此类测试的IEEE标准4对测试进行了相应的分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信