Vijendra Kumar Dubey, Ankit Singhal, H. Suryawanshi
{"title":"High efficient AC/DC Converter For micro-hydro-power plant for DC grid","authors":"Vijendra Kumar Dubey, Ankit Singhal, H. Suryawanshi","doi":"10.1109/ICRAIE.2014.6909163","DOIUrl":null,"url":null,"abstract":"In this paper, a single-phase two-stage zero-voltage-transition zero-current-transition pulse-width-modulation power-factor-correction (ZVT-ZCT-PWM-PFC) AC/DC boost converter with active snubber cell is presented, which can be interfaced with micro-hydro power plant and can be used for telecommunication, data center, and commercial building applications. Snubber cell facilitate all semiconductor switches to undergo soft-switching for every switching period. Proposed Converter operates in continuous-conduction-mode (CCM) and uses average current control scheme for PFC. Nearly unity-power-factor (UPF) operation is achieved for wide range of load. Design and analysis of a ZVT-ZCT-PWM PFC boost converter rated at 1 kW, output voltage 400 V, operating at 100 kHz, fed from AC voltage of 230 V RMS is presented. Proposed schematic is simulated in PSIM 9.0 and simulation results are provided. An efficiency of 97.8% and power factor above 0.998 is achieved at nominal power.","PeriodicalId":355706,"journal":{"name":"International Conference on Recent Advances and Innovations in Engineering (ICRAIE-2014)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Recent Advances and Innovations in Engineering (ICRAIE-2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRAIE.2014.6909163","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
In this paper, a single-phase two-stage zero-voltage-transition zero-current-transition pulse-width-modulation power-factor-correction (ZVT-ZCT-PWM-PFC) AC/DC boost converter with active snubber cell is presented, which can be interfaced with micro-hydro power plant and can be used for telecommunication, data center, and commercial building applications. Snubber cell facilitate all semiconductor switches to undergo soft-switching for every switching period. Proposed Converter operates in continuous-conduction-mode (CCM) and uses average current control scheme for PFC. Nearly unity-power-factor (UPF) operation is achieved for wide range of load. Design and analysis of a ZVT-ZCT-PWM PFC boost converter rated at 1 kW, output voltage 400 V, operating at 100 kHz, fed from AC voltage of 230 V RMS is presented. Proposed schematic is simulated in PSIM 9.0 and simulation results are provided. An efficiency of 97.8% and power factor above 0.998 is achieved at nominal power.