Impedance characteristics of loop closing device based on improved phase shifting transformer

Zhi Xu, Jianxiong Tang, Hongsheng Ma, Yupeng Jiang, Junpeng Li, Yongchun Yang
{"title":"Impedance characteristics of loop closing device based on improved phase shifting transformer","authors":"Zhi Xu, Jianxiong Tang, Hongsheng Ma, Yupeng Jiang, Junpeng Li, Yongchun Yang","doi":"10.1117/12.2689880","DOIUrl":null,"url":null,"abstract":"With the increasing reliability of power supply in distribution networks, loop closing operation is often required to achieve non-stop load transfer. Firstly, the loop closing device based on improved phase shifting transformer (IPST) can be effectively used in complex loop closing scenarios such as three-phase asymmetry and voltage magnitude difference between the buses on both sides of the loop closing point of the distribution network, considering that the internal impedance of the loop closing device has a certain influence on the quality of the loop transfer voltage. Secondly, the mathematical model of IPST equivalent impedance is established based on the basic principle of transformer, and the expressions of IPST equivalent impedance calculation and the factors affecting the size are derived and analyzed. Finally, the correctness of the proposed IPST-based impedance calculation expression for the loop closing device is verified by MATLAB and PSCAD/EMTDC simulation platform.","PeriodicalId":118234,"journal":{"name":"4th International Conference on Information Science, Electrical and Automation Engineering","volume":"38 3-4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"4th International Conference on Information Science, Electrical and Automation Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2689880","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With the increasing reliability of power supply in distribution networks, loop closing operation is often required to achieve non-stop load transfer. Firstly, the loop closing device based on improved phase shifting transformer (IPST) can be effectively used in complex loop closing scenarios such as three-phase asymmetry and voltage magnitude difference between the buses on both sides of the loop closing point of the distribution network, considering that the internal impedance of the loop closing device has a certain influence on the quality of the loop transfer voltage. Secondly, the mathematical model of IPST equivalent impedance is established based on the basic principle of transformer, and the expressions of IPST equivalent impedance calculation and the factors affecting the size are derived and analyzed. Finally, the correctness of the proposed IPST-based impedance calculation expression for the loop closing device is verified by MATLAB and PSCAD/EMTDC simulation platform.
基于改进型移相变压器的闭环装置阻抗特性研究
随着配电网供电可靠性的提高,往往需要合闸运行来实现负荷的不间断转移。首先,考虑到闭环装置内部阻抗对回路传递电压质量有一定影响,基于改进型移相变压器(IPST)的闭环装置可以有效地应用于配电网闭环点两侧母线三相不对称、电压幅值差等复杂的闭环场景。其次,根据变压器的基本原理,建立了IPST等效阻抗的数学模型,推导并分析了IPST等效阻抗的计算表达式及影响其大小的因素。最后,通过MATLAB和PSCAD/EMTDC仿真平台验证了所提出的基于ipst的闭环器件阻抗计算表达式的正确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信