{"title":"An Adaptive Threshold Algorithm Combining Shifting Window Difference and Forward-Backward Difference in Real-Time R-Wave Detection","authors":"Lihuang She, Guohua Wang, Shi Zhang, Jinshuan Zhao","doi":"10.1109/CISP.2009.5304666","DOIUrl":null,"url":null,"abstract":"Most ECG diagnosis techniques require an accurate detection of the R-wave, so R-wave detection is important in ECG signal analysis. This paper presents a new real-time R-wave detection algorithm combining adaptive Shifting Window Dif- ference Threshold (SWDT) and Forward-Backward Difference Threshold (FBDT). The algorithm can eliminate or weaken the impact of the high P-wave, high T-wave and other high-frequency interference signals onto the detection of R-wave. It can solve the problem of heavily loaded computation caused by the complicated algorithm of the traditional theory, and has been implemented on a Portable Single-lead ECG Monitor (PSEM) developed by authors. Finally, the algorithm was simulated by the American MIT-BIH Arrhythmia Database (1) with an average detection error rate (DER) 0.2%. Some real data was also collected by our PSEM from several patients. Experimental results indicated that the proposed algorithm was simple, effective, robust, accurate and suitable for application in the embedded system.","PeriodicalId":263281,"journal":{"name":"2009 2nd International Congress on Image and Signal Processing","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 2nd International Congress on Image and Signal Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CISP.2009.5304666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

Most ECG diagnosis techniques require an accurate detection of the R-wave, so R-wave detection is important in ECG signal analysis. This paper presents a new real-time R-wave detection algorithm combining adaptive Shifting Window Dif- ference Threshold (SWDT) and Forward-Backward Difference Threshold (FBDT). The algorithm can eliminate or weaken the impact of the high P-wave, high T-wave and other high-frequency interference signals onto the detection of R-wave. It can solve the problem of heavily loaded computation caused by the complicated algorithm of the traditional theory, and has been implemented on a Portable Single-lead ECG Monitor (PSEM) developed by authors. Finally, the algorithm was simulated by the American MIT-BIH Arrhythmia Database (1) with an average detection error rate (DER) 0.2%. Some real data was also collected by our PSEM from several patients. Experimental results indicated that the proposed algorithm was simple, effective, robust, accurate and suitable for application in the embedded system.
实时r波检测中结合移窗差和前后向差的自适应阈值算法
大多数心电诊断技术都要求准确检测r波,因此r波检测在心电信号分析中具有重要意义。提出了一种结合自适应移位窗差阈值(SWDT)和前后向差阈值(FBDT)的实时r波检测算法。该算法可以消除或减弱高p波、高t波等高频干扰信号对r波检测的影响。该方法解决了传统理论算法复杂导致计算量大的问题,并已在自行研制的便携式单导心电监护仪(PSEM)上实现。最后,采用美国MIT-BIH心律失常数据库(1)对算法进行仿真,平均检测错误率(DER)为0.2%。我们的PSEM还从几个病人那里收集了一些真实的数据。实验结果表明,该算法简单有效,鲁棒性好,精度高,适合在嵌入式系统中应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信