Relative contribution of chemico-osmosis and electro-osmosis to the experimental determination of the reflection coefficient in semipermeable clay soils

N. Guarena, A. Dominijanni, M. Manassero
{"title":"Relative contribution of chemico-osmosis and electro-osmosis to the experimental determination of the reflection coefficient in semipermeable clay soils","authors":"N. Guarena, A. Dominijanni, M. Manassero","doi":"10.3208/jgssp.v09.cpeg012","DOIUrl":null,"url":null,"abstract":"The containment performance of bentonite-based barriers is known to be influenced by the semipermeable membrane behaviour of the bentonite, which arises from the electrical interactions between the clay particles and the ionic species dissolved in the pore solution. Most of the experimental research conducted to date has provided evidence of the clay membrane behaviour, the extent of which is typically quantified through the reflection coefficient,  , when the permeant (electrolyte) solution contains a monovalent or divalent salt. Under such conditions, the osmotic counter-flow of solution is controlled to a great extent by the solute exclusion, which is also referred to as the chemico-osmotic effect. However, theoretical simulations of coupled solute transport and solvent flow suggest that, when two or more cations with different diffusivities are contained in the permeant solution, the electro-osmotic effect, which stems from the condition of null electric current density, can be comparable to or even greater than the chemico-osmotic effect. The relative importance of the aforementioned contributions to multi-electrolyte systems is examined herein through the interpretation of laboratory test results from the literature pertaining to a bentonite-amended clay soil permeated with aqueous mixtures of potassium chloride (KCl) and hydrochloric acid","PeriodicalId":283909,"journal":{"name":"Japanese Geotechnical Society Special Publication","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Geotechnical Society Special Publication","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3208/jgssp.v09.cpeg012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The containment performance of bentonite-based barriers is known to be influenced by the semipermeable membrane behaviour of the bentonite, which arises from the electrical interactions between the clay particles and the ionic species dissolved in the pore solution. Most of the experimental research conducted to date has provided evidence of the clay membrane behaviour, the extent of which is typically quantified through the reflection coefficient,  , when the permeant (electrolyte) solution contains a monovalent or divalent salt. Under such conditions, the osmotic counter-flow of solution is controlled to a great extent by the solute exclusion, which is also referred to as the chemico-osmotic effect. However, theoretical simulations of coupled solute transport and solvent flow suggest that, when two or more cations with different diffusivities are contained in the permeant solution, the electro-osmotic effect, which stems from the condition of null electric current density, can be comparable to or even greater than the chemico-osmotic effect. The relative importance of the aforementioned contributions to multi-electrolyte systems is examined herein through the interpretation of laboratory test results from the literature pertaining to a bentonite-amended clay soil permeated with aqueous mixtures of potassium chloride (KCl) and hydrochloric acid
化学渗透和电渗透对半透性粘土反射系数实验测定的相对贡献
已知膨润土基屏障的封闭性能受到膨润土半透膜行为的影响,这是由粘土颗粒与溶解在孔隙溶液中的离子之间的电相互作用产生的。迄今为止进行的大多数实验研究都提供了粘土膜行为的证据,其程度通常通过反射系数来量化,当渗透(电解质)溶液含有一价或二价盐时。在这种条件下,溶液的渗透逆流在很大程度上受到溶质排斥的控制,这也被称为化学渗透效应。然而,溶质输运和溶剂流动耦合的理论模拟表明,当渗透溶液中含有两种或两种以上具有不同扩散率的阳离子时,由零电流密度条件产生的电渗透效应可以与化学渗透效应相当甚至更大。上述对多电解质系统的贡献的相对重要性,在此通过对与膨润土改性粘土土壤渗透氯化钾(KCl)和盐酸的水混合物相关的文献的实验室测试结果的解释来检验
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信