{"title":"CAPACITY OF SUNTER C RIVER IN NORTH JAKARTA","authors":"M. Imamuddin, Muhammad Lutfi Fadilah","doi":"10.24853/ijcei.1.1.1-13","DOIUrl":null,"url":null,"abstract":"Sunter C river is located on Yos Sudarso street at coordinates 6°8'32,63\" South Latitude, 106°53'25,78\" East Longitude and downstream Sunter C river is located on Sunter Barat river street coordinates 6°8'24,78\" South Latitude, 106°51'24.68\" East Longitude. In area around the Sunter C river, there are still frequent floods every time the rainy season arrives because of the narrowing of canal section in upstream area of Sunter C river and Sunter C river water can’t flow gravitationally to Sentiong river because the base elevation of Sentiong river is higher than Sunter C river. From the above conditions, it’s necessary to analyze the problem of flooding in Sunter C river area to find out whether Sunter C river can still accommodate water discharge based on rainfall in the last 10 years and does the Sunter C river need normalization. Based on the results of manual calculations and HEC-RAS application, the Sunter C river can’t accommodate water discharge based on rainfall for the last 10 years of 15.88 m3/s. At point 0 - point 3 it is necessary to normalize by widening the cross-section from 3.6 m to 8 m and at point 4 from 4.8 m to 8 m.","PeriodicalId":389729,"journal":{"name":"International Journal of Civil Engineering and Infrastructure","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Civil Engineering and Infrastructure","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24853/ijcei.1.1.1-13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Sunter C river is located on Yos Sudarso street at coordinates 6°8'32,63" South Latitude, 106°53'25,78" East Longitude and downstream Sunter C river is located on Sunter Barat river street coordinates 6°8'24,78" South Latitude, 106°51'24.68" East Longitude. In area around the Sunter C river, there are still frequent floods every time the rainy season arrives because of the narrowing of canal section in upstream area of Sunter C river and Sunter C river water can’t flow gravitationally to Sentiong river because the base elevation of Sentiong river is higher than Sunter C river. From the above conditions, it’s necessary to analyze the problem of flooding in Sunter C river area to find out whether Sunter C river can still accommodate water discharge based on rainfall in the last 10 years and does the Sunter C river need normalization. Based on the results of manual calculations and HEC-RAS application, the Sunter C river can’t accommodate water discharge based on rainfall for the last 10 years of 15.88 m3/s. At point 0 - point 3 it is necessary to normalize by widening the cross-section from 3.6 m to 8 m and at point 4 from 4.8 m to 8 m.