INVESTIGATION OF MEASUREMENT ERROR OF GEOMETRIC PARAMETERS OF PARTS DEPENDING ON THE COLOR OF THE SURFACE COATING IN LASER SCANNING OPTOELECTRONIC MEASURING SYSTEMS
A. V. Shulepov, P. Win
求助PDF
{"title":"INVESTIGATION OF MEASUREMENT ERROR OF GEOMETRIC PARAMETERS OF PARTS DEPENDING ON THE COLOR OF THE SURFACE COATING IN LASER SCANNING OPTOELECTRONIC MEASURING SYSTEMS","authors":"A. V. Shulepov, P. Win","doi":"10.21685/2307-5538-2019-1-8","DOIUrl":null,"url":null,"abstract":"© Шулепов А. В., Пьей Сони Вин, 2019 Измерение. Мониторинг. Управление. Контроль Measuring. Monitoring. Management. Control 56 rameters for the quantitative estimation of the error of measurement of coordinates are proposed. Results. A significant influence of the surface color on the measurement error of the coordinates of the points is established. In this case, the greatest errors occur when scanning surfaces with black, green, blue, orange, red color. The error value for the most unfavorable color options reaches up to 3 mm in scope and 0,7 mm in standard deviation. The investigated error when painting the surface in the colors of light tones is reduced several times, in particular, its root mean square value was 0,035 mm. Conclusions. The developed technique and the results can be used to assess the effect of surface color on the measurement error of the coordinates of the points of scanning measuring systems of other types, built on the principles of triangulation, photogrammetry. К л ю ч е в ы е с л о в а: цвет, погрешность, оптоэлектронные сканирующие системы. K e y w o r d s: color, error, optoelectronic scanning systems. Введение Измерения геометрических параметров деталей сложной формы часто выполняются с применением координатных методов. Такие методы позволяют получить трехмерную геометрическую модель объекта и реализуются с помощью координатно-измерительных машин (КИМ) и оптоэлектронных бесконтактных сканирующих систем. Преимущества оптоэлектронных бесконтактных систем перед КИМ заключаются в высоком быстродействии и в возможности получения значительных массивов координат измеренных точек поверхностей деталей, расположенных с высокой плотностью [1]. Типовая схема трехкоординатной лазерной сканирующей оптоэлектронной измерительной системы (ЛСОИС) представлена на рис. 1. Сканируемая деталь 1 установлена на поворотном столе 2. Сканирующая оптоэлектронная система включает излучатель – лазер 3, цифровую видеокамеру 4 на основе ПЗС-матрицы, которая установлена на подвижной каретке 5, может перемещаться в вертикальном направлении Z и совершать угловые перемещения φ2. Координата сканируемой точки α {X, Y, Z} определяется по результатам обработки перемещений поворотного стола φ1 и сканирующей системы φ2 и Z: α { } 1 2 , , (( , , ), м, м), X Y Z f Z Y Z = φ φ (1) где Yм и Zм – координаты изображения точки α на ПЗС-матрице. Рис. 1. Схема трехкоординатной сканирующей оптоэлектронной измерительной системы","PeriodicalId":239916,"journal":{"name":"Measuring. Monitoring. Management. Control","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measuring. Monitoring. Management. Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21685/2307-5538-2019-1-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
引用
批量引用
Abstract
© Шулепов А. В., Пьей Сони Вин, 2019 Измерение. Мониторинг. Управление. Контроль Measuring. Monitoring. Management. Control 56 rameters for the quantitative estimation of the error of measurement of coordinates are proposed. Results. A significant influence of the surface color on the measurement error of the coordinates of the points is established. In this case, the greatest errors occur when scanning surfaces with black, green, blue, orange, red color. The error value for the most unfavorable color options reaches up to 3 mm in scope and 0,7 mm in standard deviation. The investigated error when painting the surface in the colors of light tones is reduced several times, in particular, its root mean square value was 0,035 mm. Conclusions. The developed technique and the results can be used to assess the effect of surface color on the measurement error of the coordinates of the points of scanning measuring systems of other types, built on the principles of triangulation, photogrammetry. К л ю ч е в ы е с л о в а: цвет, погрешность, оптоэлектронные сканирующие системы. K e y w o r d s: color, error, optoelectronic scanning systems. Введение Измерения геометрических параметров деталей сложной формы часто выполняются с применением координатных методов. Такие методы позволяют получить трехмерную геометрическую модель объекта и реализуются с помощью координатно-измерительных машин (КИМ) и оптоэлектронных бесконтактных сканирующих систем. Преимущества оптоэлектронных бесконтактных систем перед КИМ заключаются в высоком быстродействии и в возможности получения значительных массивов координат измеренных точек поверхностей деталей, расположенных с высокой плотностью [1]. Типовая схема трехкоординатной лазерной сканирующей оптоэлектронной измерительной системы (ЛСОИС) представлена на рис. 1. Сканируемая деталь 1 установлена на поворотном столе 2. Сканирующая оптоэлектронная система включает излучатель – лазер 3, цифровую видеокамеру 4 на основе ПЗС-матрицы, которая установлена на подвижной каретке 5, может перемещаться в вертикальном направлении Z и совершать угловые перемещения φ2. Координата сканируемой точки α {X, Y, Z} определяется по результатам обработки перемещений поворотного стола φ1 и сканирующей системы φ2 и Z: α { } 1 2 , , (( , , ), м, м), X Y Z f Z Y Z = φ φ (1) где Yм и Zм – координаты изображения точки α на ПЗС-матрице. Рис. 1. Схема трехкоординатной сканирующей оптоэлектронной измерительной системы
激光扫描光电测量系统中表面涂层颜色对零件几何参数测量误差的影响
©Шулепов А。В。, Пьей Сони Вин, 2019 Измерение。Мониторинг。Управление。Контроль测量。监控。管理。提出了56个控制参数对坐标测量误差的定量估计。结果。建立了表面颜色对点坐标测量误差的显著影响。在这种情况下,最大的误差发生在扫描带有黑色、绿色、蓝色、橙色、红色的表面时。最不利的颜色选项的误差值在范围内达到3mm,在标准偏差中达到0.7 mm。研究结果表明,以浅色调绘制表面时的误差减小了几倍,其均方根值为0.035 mm。结论。所开发的技术和结果可用于评估基于三角测量、摄影测量原理的其他类型扫描测量系统的表面颜色对点坐标测量误差的影响。Ключевыеслова:цвет,погрешность,оптоэлектронныесканирующиесистемы。主要有:彩色、误差、光电扫描系统。ВведениеИзмерениягеометрическихпараметровдеталейсложнойформычастовыполняютсясприменениемкоординатныхметодов。Такиеметодыпозволяютполучитьтрехмернуюгеометрическуюмодельобъектаиреализуютсяспомощьюкоординатно——измерительныхмашин(КИМ)иоптоэлектронныхбесконтактныхсканирующихсистем。ПреимуществаоптоэлектронныхбесконтактныхсистемпередКИМзаключаютсяввысокомбыстродействиииввозможностиполучениязначительныхмассивовкоординатизмеренныхточекповерхностейдеталей,расположенныхсвысокойплотностью[1]。Типоваясхематрехкоординатнойлазернойсканирующейоптоэлектроннойизмерительнойсистемы(ЛСОИС)представленанарис。1. Сканируемаядеталь1установленанаповоротномстоле2。Сканирующаяоптоэлектроннаясистемавключаетизлучатель——лазер3цифровуювидеокамер4унаосновеПЗС-матрицы,котораяустановленанаподвижнойкаретк5еможетперемещатьсяввертикальномнаправленииZисовершатьугловыеперемещенияφ2。Координатасканируемойточкиα{X, Y, Z}определяетсяпорезультатамобработкиперемещенийповоротногостолаφ1исканирующейсистемыφ2иZ:α{}1 2 , , (( , , ), мм),X Y Y Z f Z Z =φφ(1)гдеYммиZ -координатыизображенияточкиαнаПЗС-матрице。Рис。1. Схематрехкоординатнойсканирующейоптоэлектроннойизмерительнойсистемы
本文章由计算机程序翻译,如有差异,请以英文原文为准。