Static tests on instrumented piles affected by residual load

B. Fellenius
{"title":"Static tests on instrumented piles affected by residual load","authors":"B. Fellenius","doi":"10.1179/1937525515Y.0000000001","DOIUrl":null,"url":null,"abstract":"Abstract Analysis of results from a static loading tests on an instrumented pile usually assumes that the gage determined loads represent the true loads in the test pile. However, more often than not, residual load will have been present in the pile at the start of the static test. Disregarding these in the analysis will misrepresent the load–movement response and the loads determined from the strain–gage instrumentation, as presented in the paper. The results of three static loading tests: a 400 mm diameter, 45 m long, concrete filled, closed toe, steel pipe pile driven in soft clay, a 460 mm diameter, 22 m long bored pile (screw pile) in silt and sand and stiff clay, and a 600 mm diameter, 15 m long, jacked-in concrete pile in a residual, dense, silty sandy weathered sandstone. The measured load distributions are corrected for residual load, demonstrating the interdependence of the distributions of “False” and “True” distributions of load.","PeriodicalId":272645,"journal":{"name":"DFI Journal - The Journal of the Deep Foundations Institute","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"DFI Journal - The Journal of the Deep Foundations Institute","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1179/1937525515Y.0000000001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Abstract Analysis of results from a static loading tests on an instrumented pile usually assumes that the gage determined loads represent the true loads in the test pile. However, more often than not, residual load will have been present in the pile at the start of the static test. Disregarding these in the analysis will misrepresent the load–movement response and the loads determined from the strain–gage instrumentation, as presented in the paper. The results of three static loading tests: a 400 mm diameter, 45 m long, concrete filled, closed toe, steel pipe pile driven in soft clay, a 460 mm diameter, 22 m long bored pile (screw pile) in silt and sand and stiff clay, and a 600 mm diameter, 15 m long, jacked-in concrete pile in a residual, dense, silty sandy weathered sandstone. The measured load distributions are corrected for residual load, demonstrating the interdependence of the distributions of “False” and “True” distributions of load.
受残余荷载影响的仪表桩静力试验
摘要在分析仪器桩静力荷载试验结果时,通常假定仪器测得的荷载代表测试桩的真实荷载。然而,通常情况下,在静力试验开始时,残余荷载将存在于桩中。如本文所述,在分析中忽略这些将歪曲载荷-运动响应和由应变计仪器确定的载荷。三个静荷载试验的结果:在软粘土中打入直径400毫米、长45米、混凝土填充、闭趾的钢管桩,在粉砂和硬粘土中打入直径460毫米、长22米的钻孔桩(螺旋桩),以及在残余、致密、粉砂质风化砂岩中插入直径600毫米、长15米的混凝土桩。测量的负载分布对剩余负载进行了校正,证明了负载“假”分布和“真”分布的相互依赖性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信