{"title":"Cryogenic performance of HEMT amplifiers at 340GHz and 670GHz","authors":"T. Reck, W. Deal, G. Chattopadhyay","doi":"10.1109/MWSYM.2014.6848250","DOIUrl":null,"url":null,"abstract":"The cryogenic performance of HEMT amplifiers operating above 300 GHz is presented for the first time. InP HEMT amplifiers designed for room temperature operation are cooled to 25 K and their sensitivity is characterized using the Y-factor method. Minimum noise temperatures of 400 K and 550 K are achieved at 340 GHz and 670 GHz, respectively.","PeriodicalId":262816,"journal":{"name":"2014 IEEE MTT-S International Microwave Symposium (IMS2014)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE MTT-S International Microwave Symposium (IMS2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.2014.6848250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12
Abstract
The cryogenic performance of HEMT amplifiers operating above 300 GHz is presented for the first time. InP HEMT amplifiers designed for room temperature operation are cooled to 25 K and their sensitivity is characterized using the Y-factor method. Minimum noise temperatures of 400 K and 550 K are achieved at 340 GHz and 670 GHz, respectively.