First results from the BNL/Penn PET-MRI system for whole body rodent imaging at 9.4T

M. Budassi, M. Purschke, J. Fried, T. Cao, S. Stoll, E. Gualtieri, J. Karp, P. O'connor, D. Schlyer, C. Woody, P. Vaska
{"title":"First results from the BNL/Penn PET-MRI system for whole body rodent imaging at 9.4T","authors":"M. Budassi, M. Purschke, J. Fried, T. Cao, S. Stoll, E. Gualtieri, J. Karp, P. O'connor, D. Schlyer, C. Woody, P. Vaska","doi":"10.1109/NSSMIC.2012.6551626","DOIUrl":null,"url":null,"abstract":"A new PET system has been developed for the purposes of simultaneous PET/MR whole body rodent imaging in conjunction with a Varian large-bore 9.4T MRI system with a commercial Insight birdcage coil. The detector and readout technology is based on that developed for the RatCAP PET system, resulting in a highly robust and compact design that is compatible with MRI systems at the highest field strength. Testing of the full readout chain has shown a successful implementation of both modalities, with indications of only modest cross-interference on MRI image quality or PET detection efficiency. The final design cycle is complete, and supports operation of the full system with upgrades to the data acquisition electronics, firmware, and software. First results from the complete PET system will be presented, including preliminary imaging and tests of interference between modalities.","PeriodicalId":187728,"journal":{"name":"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)","volume":"1857 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2012.6551626","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A new PET system has been developed for the purposes of simultaneous PET/MR whole body rodent imaging in conjunction with a Varian large-bore 9.4T MRI system with a commercial Insight birdcage coil. The detector and readout technology is based on that developed for the RatCAP PET system, resulting in a highly robust and compact design that is compatible with MRI systems at the highest field strength. Testing of the full readout chain has shown a successful implementation of both modalities, with indications of only modest cross-interference on MRI image quality or PET detection efficiency. The final design cycle is complete, and supports operation of the full system with upgrades to the data acquisition electronics, firmware, and software. First results from the complete PET system will be presented, including preliminary imaging and tests of interference between modalities.
BNL/Penn PET-MRI系统对全身啮齿动物进行9.4T成像的第一个结果
一种新的PET系统已经开发出来,用于同时进行PET/MR全身啮齿动物成像,并与瓦里安大口径9.4T MRI系统结合使用,该系统带有商业Insight鸟笼线圈。检测器和读出技术基于为RatCAP PET系统开发的技术,具有高度坚固和紧凑的设计,可在最高场强下与MRI系统兼容。完整读出链的测试显示了两种模式的成功实施,只有适度的交叉干扰对MRI图像质量或PET检测效率的迹象。最终的设计周期已经完成,并通过升级数据采集电子设备、固件和软件来支持整个系统的运行。将介绍完整PET系统的第一批结果,包括初步成像和模式之间的干扰测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信