Accuracy and reliability of two methods of screening for hypoglycemia in neonates.

K L Ho, H L Loke, K W Tan
{"title":"Accuracy and reliability of two methods of screening for hypoglycemia in neonates.","authors":"K L Ho,&nbsp;H L Loke,&nbsp;K W Tan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Two hundred and six neonates were screened for hypoglycemia using two glucose test strips and their results compared with a simultaneous blood sugar obtained from the Beckman's glucose analyser. Both test strips, Reflotest hypoglycemia and the Reflolux (BM test glycemia 20-800) gave rapid estimates of blood sugar readings. In this study, these two strips were assessed in their accuracy and reliability to detect neonatal hypoglycaemia (blood sugar levels less than 2.2 mmol/L). The sensitivity and specificity of the two test strips are 0.82 and 0.90 for Reflotest, and 0.88 and 0.81 for Reflolux respectively. Hence we conclude that both Reflotest and Reflolux are sensitive in detecting blood sugar levels at or below 2.2 mmol/L (40 mg/dl) although Reflolux is less specific. A laboratory result is mandatory before the diagnosis and prognosis of hypoglycemia is made.</p>","PeriodicalId":76683,"journal":{"name":"The Journal of the Singapore Paediatric Society","volume":"33 3-4","pages":"156-8"},"PeriodicalIF":0.0000,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of the Singapore Paediatric Society","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Two hundred and six neonates were screened for hypoglycemia using two glucose test strips and their results compared with a simultaneous blood sugar obtained from the Beckman's glucose analyser. Both test strips, Reflotest hypoglycemia and the Reflolux (BM test glycemia 20-800) gave rapid estimates of blood sugar readings. In this study, these two strips were assessed in their accuracy and reliability to detect neonatal hypoglycaemia (blood sugar levels less than 2.2 mmol/L). The sensitivity and specificity of the two test strips are 0.82 and 0.90 for Reflotest, and 0.88 and 0.81 for Reflolux respectively. Hence we conclude that both Reflotest and Reflolux are sensitive in detecting blood sugar levels at or below 2.2 mmol/L (40 mg/dl) although Reflolux is less specific. A laboratory result is mandatory before the diagnosis and prognosis of hypoglycemia is made.

两种筛查新生儿低血糖的方法的准确性和可靠性。
使用两条血糖试纸对256名新生儿进行低血糖筛查,并将其结果与贝克曼血糖分析仪同时获得的血糖进行比较。两种测试条,refflotest低血糖和refolux (BM测试血糖20-800)都能快速估计血糖读数。在本研究中,评估了这两种试纸检测新生儿低血糖(血糖水平低于2.2 mmol/L)的准确性和可靠性。两种试纸对Reflotest的敏感性和特异性分别为0.82和0.90,对Reflolux的敏感性和特异性分别为0.88和0.81。因此,我们得出结论,Reflotest和Reflolux在检测血糖水平在2.2 mmol/L (40 mg/dl)或以下时都很敏感,尽管Reflolux的特异性较差。在低血糖的诊断和预后之前,实验室结果是强制性的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信