Frequency drift for quartz resonator irradiated by CO gamma ray

S. Obara, M. Koyama, A. Chiba, H. Fukuda, H. Ohba
{"title":"Frequency drift for quartz resonator irradiated by CO gamma ray","authors":"S. Obara, M. Koyama, A. Chiba, H. Fukuda, H. Ohba","doi":"10.1109/FREQ.1989.68912","DOIUrl":null,"url":null,"abstract":"An investigation and research is reported into the radiation environment of a geostationary satellite and the radiation resistance of quartz resonators to be installed in artificial satellites. The total absorbed dose of a synchronous satellite in a geostationary orbit reaches about 1*10/sup 4/ Gy in ten years. For example, the rate of change of the frequency of a quartz resonator manufactured from an unswept crystal with a Q-value of about 2.8 million was about 0.2*10/sup -6/ at a total absorbed dose of 1*10/sup 5/.<<ETX>>","PeriodicalId":294361,"journal":{"name":"Proceedings of the 43rd Annual Symposium on Frequency Control","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 43rd Annual Symposium on Frequency Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FREQ.1989.68912","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An investigation and research is reported into the radiation environment of a geostationary satellite and the radiation resistance of quartz resonators to be installed in artificial satellites. The total absorbed dose of a synchronous satellite in a geostationary orbit reaches about 1*10/sup 4/ Gy in ten years. For example, the rate of change of the frequency of a quartz resonator manufactured from an unswept crystal with a Q-value of about 2.8 million was about 0.2*10/sup -6/ at a total absorbed dose of 1*10/sup 5/.<>
CO射线辐照石英谐振腔的频率漂移
对地球静止卫星的辐射环境和人造卫星上安装的石英谐振器的抗辐射性能进行了调查研究。地球静止轨道上一颗同步卫星十年的总吸收剂量约为1*10/sup 4/ Gy。例如,在总吸收剂量为1*10/sup 5/时,由q值约为280万的未扫频晶体制成的石英谐振器的频率变化率约为0.2*10/sup -6/。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信