{"title":"A 0.026mm2 capacitance-to-digital converter for biotelemetry applications using a charge redistribution technique","authors":"Kota Tanaka, Y. Kuramochi, T. Kurashina, K. Okada, Akira Matsuzawa","doi":"10.1109/ASSCC.2007.4425776","DOIUrl":null,"url":null,"abstract":"This paper proposes a direct capacitance-to-digital converter (CDC) for biotelemetry applications. The proposed circuit is based on a charge redistribution technique using a capacitive sensor and a ranging capacitor array. The circuit does not require accurate reference voltages, so it is robust for fluctuation of supply voltage. Output-code range can be dynamically zoomed in arbitrary capacitance range of sensor output by using the ranging capacitor array. An 8-bit converter with an active area of 0.026 mm2, consuming 0.9 nJ per sample, is demonstrated. The proposed circuit maintains its performance even in the condition of 28% fluctuations in supply voltage. Measurement results of the readout circuit are also demonstrated, which shows that the proposed circuit can work well in the presence of large parasitic capacitances.","PeriodicalId":186095,"journal":{"name":"2007 IEEE Asian Solid-State Circuits Conference","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"52","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Asian Solid-State Circuits Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASSCC.2007.4425776","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 52

Abstract

This paper proposes a direct capacitance-to-digital converter (CDC) for biotelemetry applications. The proposed circuit is based on a charge redistribution technique using a capacitive sensor and a ranging capacitor array. The circuit does not require accurate reference voltages, so it is robust for fluctuation of supply voltage. Output-code range can be dynamically zoomed in arbitrary capacitance range of sensor output by using the ranging capacitor array. An 8-bit converter with an active area of 0.026 mm2, consuming 0.9 nJ per sample, is demonstrated. The proposed circuit maintains its performance even in the condition of 28% fluctuations in supply voltage. Measurement results of the readout circuit are also demonstrated, which shows that the proposed circuit can work well in the presence of large parasitic capacitances.
0.026mm2电容-数字转换器,用于生物遥测应用,采用电荷再分配技术
本文提出了一种用于生物遥测应用的直接电容-数字转换器(CDC)。所提出的电路是基于使用电容式传感器和测距电容阵列的电荷再分配技术。该电路不需要精确的参考电压,对电源电压波动具有较强的鲁棒性。利用量程电容阵列,可以在传感器输出的任意电容范围内动态放大输出码范围。演示了一个8位转换器,其有效面积为0.026 mm2,每个样品消耗0.9 nJ。所提出的电路即使在电源电压波动28%的情况下也能保持其性能。对读出电路的测量结果也进行了验证,结果表明该电路在较大寄生电容的情况下也能很好地工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信