{"title":"Corona and electrocorrosion of the stator windings of HV machines and on-site test of the corona inception voltage at the plateau","authors":"Lu Pei-Zeng","doi":"10.1109/CEIDP.1986.7726488","DOIUrl":null,"url":null,"abstract":"This paper investigates epoxy-insulated high voltage machines, which utilize corona protection techniques. An attempt was made using a multiple regression analysis to derive the governing equation of corona inception voltage obtained from in-situ tests. The influence of environmental factors is also discussed.","PeriodicalId":354533,"journal":{"name":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1986","volume":"59 4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1986-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1986","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1986.7726488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper investigates epoxy-insulated high voltage machines, which utilize corona protection techniques. An attempt was made using a multiple regression analysis to derive the governing equation of corona inception voltage obtained from in-situ tests. The influence of environmental factors is also discussed.