Relation between parameters of myocardial mechanics and ventricular arterial coupling: A three-dimensional speckle-tracking study in healthy adults

M. Esmaeilzadeh., H. Salehi, Rabiya Malik, H. Bakhshandeh, Ayan R. Patel, N. Pandian
{"title":"Relation between parameters of myocardial mechanics and ventricular arterial coupling: A three-dimensional speckle-tracking study in healthy adults","authors":"M. Esmaeilzadeh., H. Salehi, Rabiya Malik, H. Bakhshandeh, Ayan R. Patel, N. Pandian","doi":"10.5812/acvi.33216","DOIUrl":null,"url":null,"abstract":"Background: Understanding the relation between ventricular-arterial coupling (VAC) and myocardial mechanical parameters could offer an adjunctive perspective on left ventricular function. Objectives: Our aim was to study the relation between VAC and the parameters of myocardial mechanics using three-dimensional speckle-tracking echocardiography (3DSTE). Patients and Methods: We studied 68 normal participants (mean age, 35 ± 12.2 y; 36 [53%] males). VAC was measured by the ratio of arterial elastance (Ea) to ventricular elastance (Ees). The peak systolic value of longitudinal strain (LS), circumferential strain (CS), radial strain, three-dimensional global strain (3DGS), apical rotation, torsion, and twist and their time to peak were calculated. Results: Almost all deformation indices were higher in the women than in the men. LS (r = -0.41, P < 0.01), twist (r = 0.26, P < 0.03), rotation (r = 0.41, P < 0.01), and 3DGS (r = - 0.39, P < 0.01) were associated with age. Although significant associations were found between VAC and Ea or Ees in the men and women, no relation was found between Ea and Ees in both sexes (r = 0.07 in men and r = 0.08 in women). Indeed, VAC had a stronger association with Ea than with Ees (r = 0.708 vs. r = -0.537). Ees and VAC were related to torsion (r = 0.30 vs. r = -0.37; both P < 0.05); and Ea, Ees, and VAC were also associated with CS (r = 0.64, r = -0.45, and r = 0.79; all P < 0.05) and 3DGS (r = -0.55, r = 0.38, and r = -0.64; all P < 0.01). Conclusions: Amongst all myocardial mechanical parameters, VAC was related to CS and 3DGS as well as torsion.","PeriodicalId":429543,"journal":{"name":"Archives of Cardiovascular Imaging","volume":"81 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Cardiovascular Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5812/acvi.33216","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Understanding the relation between ventricular-arterial coupling (VAC) and myocardial mechanical parameters could offer an adjunctive perspective on left ventricular function. Objectives: Our aim was to study the relation between VAC and the parameters of myocardial mechanics using three-dimensional speckle-tracking echocardiography (3DSTE). Patients and Methods: We studied 68 normal participants (mean age, 35 ± 12.2 y; 36 [53%] males). VAC was measured by the ratio of arterial elastance (Ea) to ventricular elastance (Ees). The peak systolic value of longitudinal strain (LS), circumferential strain (CS), radial strain, three-dimensional global strain (3DGS), apical rotation, torsion, and twist and their time to peak were calculated. Results: Almost all deformation indices were higher in the women than in the men. LS (r = -0.41, P < 0.01), twist (r = 0.26, P < 0.03), rotation (r = 0.41, P < 0.01), and 3DGS (r = - 0.39, P < 0.01) were associated with age. Although significant associations were found between VAC and Ea or Ees in the men and women, no relation was found between Ea and Ees in both sexes (r = 0.07 in men and r = 0.08 in women). Indeed, VAC had a stronger association with Ea than with Ees (r = 0.708 vs. r = -0.537). Ees and VAC were related to torsion (r = 0.30 vs. r = -0.37; both P < 0.05); and Ea, Ees, and VAC were also associated with CS (r = 0.64, r = -0.45, and r = 0.79; all P < 0.05) and 3DGS (r = -0.55, r = 0.38, and r = -0.64; all P < 0.01). Conclusions: Amongst all myocardial mechanical parameters, VAC was related to CS and 3DGS as well as torsion.
健康成人心肌力学参数与心室动脉耦合的关系:三维斑点跟踪研究
背景:了解心室-动脉耦合(VAC)与心肌力学参数的关系可以为左心室功能的研究提供辅助视角。目的:应用三维斑点跟踪超声心动图(3DSTE)研究心肌力学参数与心室电位的关系。患者和方法:我们研究了68名正常受试者(平均年龄35±12.2岁;36[53%]男性)。以动脉弹性(Ea)与心室弹性(Ees)之比测量VAC。计算纵向应变(LS)、周向应变(CS)、径向应变、三维总应变(3DGS)、根尖旋转、扭转和扭转的收缩峰值及其达到峰值的时间。结果:女性几乎所有的变形指标都高于男性。LS (r = -0.41, P < 0.01)、twist (r = 0.26, P < 0.03)、rotation (r = 0.41, P < 0.01)、3DGS (r = - 0.39, P < 0.01)与年龄相关。尽管在男性和女性中发现VAC与Ea或Ees之间存在显著关联,但在两性中没有发现Ea和Ees之间的关系(男性r = 0.07,女性r = 0.08)。事实上,VAC与Ea的相关性强于Ees (r = 0.708 vs. r = -0.537)。Ees和VAC与扭转相关(r = 0.30 vs r = -0.37;P < 0.05);Ea、Ees和VAC也与CS相关(r = 0.64、r = -0.45和r = 0.79;P < 0.05)和3DGS (r = -0.55, r = 0.38, r = -0.64;P < 0.01)。结论:各心肌力学参数中,VAC与CS、3DGS及扭转有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信