Risk analysis and research based on IEEE 1588 in Smart high voltage substation

Bian Baoyin, T. Xiaojun, Huang Xin
{"title":"Risk analysis and research based on IEEE 1588 in Smart high voltage substation","authors":"Bian Baoyin, T. Xiaojun, Huang Xin","doi":"10.1109/ISGT-ASIA.2012.6303307","DOIUrl":null,"url":null,"abstract":"This paper describes the current Smart high voltage substation where Merging Units and other protection devices require high-precision time synchronization, and analyzes the time synchronization significant role in the Smart substation. With the expansion of the IEC 61850 standard in Smart substation automation applying, the IEEE 1588 which can achieve sub-microsecond level of accuracy seems to be a promising way to satisfy the synchronization requirements of Smart substation. The authors provide brief introduction to the time synchronization of Smart substation, then provide details of IEEE 1588 standard for precise time synchronization and describe the potential risks of the IEEE 1588 time synchronization system implemented in the Smart high voltage substation, and finally make a thorough research of the improved methods that have successfully applied in a 330kV Smart substation in the northwestern province of China.","PeriodicalId":330758,"journal":{"name":"IEEE PES Innovative Smart Grid Technologies","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-ASIA.2012.6303307","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper describes the current Smart high voltage substation where Merging Units and other protection devices require high-precision time synchronization, and analyzes the time synchronization significant role in the Smart substation. With the expansion of the IEC 61850 standard in Smart substation automation applying, the IEEE 1588 which can achieve sub-microsecond level of accuracy seems to be a promising way to satisfy the synchronization requirements of Smart substation. The authors provide brief introduction to the time synchronization of Smart substation, then provide details of IEEE 1588 standard for precise time synchronization and describe the potential risks of the IEEE 1588 time synchronization system implemented in the Smart high voltage substation, and finally make a thorough research of the improved methods that have successfully applied in a 330kV Smart substation in the northwestern province of China.
基于IEEE 1588的智能高压变电站风险分析与研究
介绍了当前智能高压变电站中并合单元等保护装置对时间同步精度的要求,分析了时间同步在智能变电站中的重要作用。随着IEC 61850标准在智能变电站自动化应用领域的不断扩大,能够达到亚微秒级精度的IEEE 1588有望满足智能变电站的同步要求。简要介绍了智能变电站的时间同步,详细介绍了IEEE 1588精确时间同步标准,描述了IEEE 1588时间同步系统在智能高压变电站中实现的潜在风险,最后对改进方法进行了深入研究,并在西北省某330kV智能变电站中成功应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信