Z. Fang, Zhan Zhao, Fangmin Sun, Xianxiang Chen, L. Du, Huaiyong Li, Lili Tian
{"title":"The 3AHcare node: Health monitoring continuously","authors":"Z. Fang, Zhan Zhao, Fangmin Sun, Xianxiang Chen, L. Du, Huaiyong Li, Lili Tian","doi":"10.1109/HealthCom.2012.6379438","DOIUrl":null,"url":null,"abstract":"We developed and tested the Institute of Electronics, Chinese Academy of Sciences (IECAS) 3AHcare node, a health monitoring device capable of measuring a subject's ECG, blood pressure, blood oxygenation, respiration, temperature and motion - almost equivalent to the feature set of a hospital bedside patient monitor. The main contribution of this paper include: the device has been a highly integrated design incorporating the radio and all associated circuitry on a single PCB; a new noninvasive and cuff-less measurement of blood pressure using pulse wave transit time has been designed and validated. The device stores data locally on microSD flash and /or transmits via Bluetooth and/or Zigbee. We have developed a bandage vest which embeds reusable electrodes for data acquisition as well as a desktop and mobile application for real-time data telemetry. We have evaluated the performance of the device in capturing and recording ambulatory data and found the device easy to use and with high precision.","PeriodicalId":138952,"journal":{"name":"2012 IEEE 14th International Conference on e-Health Networking, Applications and Services (Healthcom)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE 14th International Conference on e-Health Networking, Applications and Services (Healthcom)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HealthCom.2012.6379438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
We developed and tested the Institute of Electronics, Chinese Academy of Sciences (IECAS) 3AHcare node, a health monitoring device capable of measuring a subject's ECG, blood pressure, blood oxygenation, respiration, temperature and motion - almost equivalent to the feature set of a hospital bedside patient monitor. The main contribution of this paper include: the device has been a highly integrated design incorporating the radio and all associated circuitry on a single PCB; a new noninvasive and cuff-less measurement of blood pressure using pulse wave transit time has been designed and validated. The device stores data locally on microSD flash and /or transmits via Bluetooth and/or Zigbee. We have developed a bandage vest which embeds reusable electrodes for data acquisition as well as a desktop and mobile application for real-time data telemetry. We have evaluated the performance of the device in capturing and recording ambulatory data and found the device easy to use and with high precision.