{"title":"Catheter with an anchoring tip for chronic joint capsule perfusion.","authors":"B D Wigness,&nbsp;F D Dorman,&nbsp;H J Robinson,&nbsp;E A Arendt,&nbsp;T R Oegema,&nbsp;T D Rohde,&nbsp;H Buchwald","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An orthopedic catheter for long-term access to the synovial joint is anchored by a hollow threaded tap that penetrates the capsule through a hole drilled in the surrounding bone. The proximal end of the catheter is connected to either an implantable drug infusion pump or an implantable access port for continuous or intermittent perfusion or sampling. Four catheters were evaluated in dogs. Three were attached to ports, the fourth to a pump. Water (one trial, 22 weeks) and hyaluronic acid (HA) (5 mg/ml; two trials of 8 weeks each) were administered through ports twice weekly in 1.5 ml boluses; 5 mg/ml HA was delivered by pump (1 trial of 33 weeks) at 0.31 ml/day.</p>","PeriodicalId":77493,"journal":{"name":"ASAIO transactions","volume":"37 3","pages":"M290-2"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO transactions","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An orthopedic catheter for long-term access to the synovial joint is anchored by a hollow threaded tap that penetrates the capsule through a hole drilled in the surrounding bone. The proximal end of the catheter is connected to either an implantable drug infusion pump or an implantable access port for continuous or intermittent perfusion or sampling. Four catheters were evaluated in dogs. Three were attached to ports, the fourth to a pump. Water (one trial, 22 weeks) and hyaluronic acid (HA) (5 mg/ml; two trials of 8 weeks each) were administered through ports twice weekly in 1.5 ml boluses; 5 mg/ml HA was delivered by pump (1 trial of 33 weeks) at 0.31 ml/day.

带锚定尖端的导管用于慢性关节囊灌注。
长期进入滑膜关节的矫形导管由一个空心螺纹丝锥固定,该丝锥通过在周围骨上钻的孔穿透囊。所述导管近端连接可植入药物输注泵或可植入接入端口,用于连续或间歇灌注或取样。在犬中评估了4个导管。其中三个连接在端口上,第四个连接在泵上。水(1次试验,22周)和透明质酸(HA) (5 mg/ml;两项试验(每次8周)通过端口给药,每周两次,每次1.5 ml;以0.31 ml/天的剂量泵送HA 5 mg/ml(33周1次)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信