Evaluation of Chest X-Ray Quality Parameters

Gumieri Dhiego Donizethe Ferreira, Marques Israel de Souza
{"title":"Evaluation of Chest X-Ray Quality Parameters","authors":"Gumieri Dhiego Donizethe Ferreira, Marques Israel de Souza","doi":"10.23937/2572-3235.1510082","DOIUrl":null,"url":null,"abstract":"Proper control of radiographic quality is important to guarantee the method high sensitivity and specificity, important factors for diagnostic complementation. It is the responsibility of the practitioner performing the radiological techniques to ensure that all chest radiographs are provided for minimal rotation, good radiographic exposure and adequate inspiration. This cross-sectional study retrospectively evaluated 456 chest radiographs in the poster anterior and lateral projection performed at a diagnostic center between May 2017 and September 2019. 45% had changes in technical parameters, of which 62% had positioning errors (rotation and asymmetry between the spinous process and medial extremity of the clavicles), 25% had errors in radiographic exposure (underexposure and overexposure) and 13% had inadequate respiratory maneuver. The observed results indicate significant deficiency of professionals regarding the minimum quality control required, as well as the need to implement a permanent education plan about the method.","PeriodicalId":306475,"journal":{"name":"International Journal of Radiology and Imaging Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Radiology and Imaging Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23937/2572-3235.1510082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Proper control of radiographic quality is important to guarantee the method high sensitivity and specificity, important factors for diagnostic complementation. It is the responsibility of the practitioner performing the radiological techniques to ensure that all chest radiographs are provided for minimal rotation, good radiographic exposure and adequate inspiration. This cross-sectional study retrospectively evaluated 456 chest radiographs in the poster anterior and lateral projection performed at a diagnostic center between May 2017 and September 2019. 45% had changes in technical parameters, of which 62% had positioning errors (rotation and asymmetry between the spinous process and medial extremity of the clavicles), 25% had errors in radiographic exposure (underexposure and overexposure) and 13% had inadequate respiratory maneuver. The observed results indicate significant deficiency of professionals regarding the minimum quality control required, as well as the need to implement a permanent education plan about the method.
胸片质量参数的评价
正确的影像学质量控制是保证该方法高灵敏度和特异性的重要因素,是辅助诊断的重要因素。实施放射技术的执业医师有责任确保所有胸部x线片都提供最小旋转,良好的放射照射和充分的启发。本横断面研究回顾性评估了2017年5月至2019年9月在诊断中心拍摄的456张胸部前位和侧位x线片。45%的患者有技术参数的改变,其中62%的患者有定位错误(棘突和锁骨内侧肢体之间的旋转和不对称),25%的患者有放射暴露错误(暴露不足和过度暴露),13%的患者有呼吸操作不足。观察到的结果表明,在所需的最低质量控制方面,专业人员存在重大缺陷,并且需要实施关于该方法的永久教育计划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信