Effect of laser phototherapy on human alveolar bone repair: micro tomographic and histomorphometrical analysis

M. Romão, M. Marques, A. Cortes, A. Horliana, M. S. Moreira, C. Lascala
{"title":"Effect of laser phototherapy on human alveolar bone repair: micro tomographic and histomorphometrical analysis","authors":"M. Romão, M. Marques, A. Cortes, A. Horliana, M. S. Moreira, C. Lascala","doi":"10.1117/12.2181041","DOIUrl":null,"url":null,"abstract":"The immediate dental implant placement in the molars region is critical, because of the high amount of bone loss and the discrepancy between the alveolar crest thickness and the dental implant platform. Laser phototherapy (LPT) improves bone repair thus could accelerate the implant placement. Twenty patients were selected for the study. Ten patients were submitted to LPT with GaAlAs diode laser (808nm) during molar extraction, immediately after, 24h, 48h, 72h, 96h and 7 days. The irradiations were applied in contact and punctual mode (100mW, 0.04cm2, 0.75J/cm2, 30s per point, 3J per point). The control group (n=10) received the same treatment; however with the power of the laser off. Forty days later samples of the tissue formed inside the sockets were obtained for further microtomography (microCTs) and histomorphometry analyses. Data were compared by the Student t test, whereas those from the different microCT parameters were compared by the Pearson correlation test (p<0.05). The relative bone volume, as well as area was significantly higher (p<0.001) in the lased than the control group. In the control group there were negative correlations between number and thickness, and between number and separation of trabecula (p<0.01). Between thickness and separation of trabecula the correlation was positive (p<0.01). The laser group showed significant negative correlation between the number and the thickness of trabecula (p<0.01). LPT accelerated bone repair. By the Pearson correlation test it was possible to infer that the lased group presented a more homogeneous trabecular configuration, which would allow earlier dental implant placement.","PeriodicalId":307847,"journal":{"name":"Biophotonics South America","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biophotonics South America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2181041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The immediate dental implant placement in the molars region is critical, because of the high amount of bone loss and the discrepancy between the alveolar crest thickness and the dental implant platform. Laser phototherapy (LPT) improves bone repair thus could accelerate the implant placement. Twenty patients were selected for the study. Ten patients were submitted to LPT with GaAlAs diode laser (808nm) during molar extraction, immediately after, 24h, 48h, 72h, 96h and 7 days. The irradiations were applied in contact and punctual mode (100mW, 0.04cm2, 0.75J/cm2, 30s per point, 3J per point). The control group (n=10) received the same treatment; however with the power of the laser off. Forty days later samples of the tissue formed inside the sockets were obtained for further microtomography (microCTs) and histomorphometry analyses. Data were compared by the Student t test, whereas those from the different microCT parameters were compared by the Pearson correlation test (p<0.05). The relative bone volume, as well as area was significantly higher (p<0.001) in the lased than the control group. In the control group there were negative correlations between number and thickness, and between number and separation of trabecula (p<0.01). Between thickness and separation of trabecula the correlation was positive (p<0.01). The laser group showed significant negative correlation between the number and the thickness of trabecula (p<0.01). LPT accelerated bone repair. By the Pearson correlation test it was possible to infer that the lased group presented a more homogeneous trabecular configuration, which would allow earlier dental implant placement.
激光光疗对人牙槽骨修复的影响:显微层析和组织形态学分析
由于牙槽嵴厚度与种植体平台之间存在差异,因此在磨牙区域立即放置种植体是至关重要的。激光光疗(LPT)可以改善骨修复,从而加快种植体的植入。20名患者被选为研究对象。10例患者分别于拔牙时、拔牙后、24h、48h、72h、96h和7d接受GaAlAs二极管激光(808nm) LPT。辐照采用接触和定时模式(100mW, 0.04cm2, 0.75J/cm2, 30s /点,3J /点)。对照组(n=10)给予相同治疗;然而,随着激光的功率关闭。40天后,获得窝内形成的组织样本,用于进一步的显微断层扫描(microct)和组织形态学分析。数据比较采用Student t检验,不同显微ct参数的数据比较采用Pearson相关检验(p<0.05)。实验组相对骨体积和骨面积均显著高于对照组(p<0.001)。对照组小梁数目与厚度、数目与分离度呈负相关(p<0.01)。小梁厚度与分离程度呈正相关(p<0.01)。激光组小梁数量与厚度呈显著负相关(p<0.01)。LPT加速骨修复。通过Pearson相关检验,可以推断出激光组呈现出更均匀的小梁结构,这将允许更早地种植牙。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信