Spatiotemporal electric field distribution in an EHV substation in view of occupational exposure

D. Harimurugan, G. S. Punekar, N. Kishore
{"title":"Spatiotemporal electric field distribution in an EHV substation in view of occupational exposure","authors":"D. Harimurugan, G. S. Punekar, N. Kishore","doi":"10.1109/DISCOVER47552.2019.9008014","DOIUrl":null,"url":null,"abstract":"With the increase in the transmission voltage levels, the effect of non-ionizing radiation (NIR) becomes a major concern. The International Commission on Non-Ionizing Radiation (ICNIRP) provides the guidelines for protection against NIR. It suggests the reference electric field (e-field) value of 10 kV/m for occupational exposure and 5 kV/m for general public exposure for the substation. In view of this, e-field prevailing in a 765 kV generating substation is studied in the present work to assess the spatiotemporal distribution using charge simulation method (CSM) based model. This should give a feel of the possible threat posed by these fields to the working personal due to NIR. The upcoming EHV substation in central India is considered with its bays, transmission lines, buses, and ground wires. The instantaneous values of e-field are computed at different instances over the 50 Hz voltage cycle, at 2 m height above the ground plane over the entire substation arena. The demo of spatiotemporal variation of e-field computed at different instants of time over a cycle using simulating charges taken from the real-number-field will be presented and discussed during the presentation. This would result in a time-space changing e-field-force, and give a feel of creation of churning of air and electric wind. This will have much higher significance at the heights were conductors are placed where the e-fields are higher. It is also shown that because of spatiotemporal variation of e-field, the rms value of e-field can be easily obtained using simulating charges taken from complex-number-field which is of significance from the point of view of ICNIRP guidelines.","PeriodicalId":274260,"journal":{"name":"2019 IEEE International Conference on Distributed Computing, VLSI, Electrical Circuits and Robotics (DISCOVER)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE International Conference on Distributed Computing, VLSI, Electrical Circuits and Robotics (DISCOVER)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DISCOVER47552.2019.9008014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With the increase in the transmission voltage levels, the effect of non-ionizing radiation (NIR) becomes a major concern. The International Commission on Non-Ionizing Radiation (ICNIRP) provides the guidelines for protection against NIR. It suggests the reference electric field (e-field) value of 10 kV/m for occupational exposure and 5 kV/m for general public exposure for the substation. In view of this, e-field prevailing in a 765 kV generating substation is studied in the present work to assess the spatiotemporal distribution using charge simulation method (CSM) based model. This should give a feel of the possible threat posed by these fields to the working personal due to NIR. The upcoming EHV substation in central India is considered with its bays, transmission lines, buses, and ground wires. The instantaneous values of e-field are computed at different instances over the 50 Hz voltage cycle, at 2 m height above the ground plane over the entire substation arena. The demo of spatiotemporal variation of e-field computed at different instants of time over a cycle using simulating charges taken from the real-number-field will be presented and discussed during the presentation. This would result in a time-space changing e-field-force, and give a feel of creation of churning of air and electric wind. This will have much higher significance at the heights were conductors are placed where the e-fields are higher. It is also shown that because of spatiotemporal variation of e-field, the rms value of e-field can be easily obtained using simulating charges taken from complex-number-field which is of significance from the point of view of ICNIRP guidelines.
职业性暴露下超高压变电站电场时空分布分析
随着传输电压水平的提高,非电离辐射(NIR)的影响成为人们关注的焦点。国际非电离辐射委员会(ICNIRP)提供了针对近红外的防护指南。建议变电站的职业暴露参考电场(e场)值为10 kV/m,一般公众暴露参考电场值为5 kV/m。鉴于此,本文以某765 kV发电变电站为研究对象,采用基于电荷模拟方法(CSM)的模型对其时空分布进行了评估。这应该能让人感觉到这些领域由于近红外对工作人员可能构成的威胁。即将在印度中部建设的超高压变电站将包括其机架、输电线路、总线和地线。在50hz电压周期内,在整个变电站场地地面以上2米高度处,计算不同情况下电场的瞬时值。在演示过程中,将展示和讨论利用从实数场中获取的模拟电荷在一个周期内不同时刻计算的电子场的时空变化。这将导致时空变化的电场力,并给人一种空气和电风搅动的感觉。在电场较高的地方放置导体时,这将具有更大的意义。由于电子场的时空变化,利用复数场的模拟电荷可以很容易地得到电子场的均方根值,这从ICNIRP准则的角度来看是有意义的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信