CdZnTe Detector Arrays For Nuclear Medicine Imaging

J. F. Butler, S.J. Friesenhahn, C. Lingren, B. Apotovsky, R. Simchon, F. Doty, W. L. Ashburn, W. Dillon
{"title":"CdZnTe Detector Arrays For Nuclear Medicine Imaging","authors":"J. F. Butler, S.J. Friesenhahn, C. Lingren, B. Apotovsky, R. Simchon, F. Doty, W. L. Ashburn, W. Dillon","doi":"10.1109/NSSMIC.1993.701724","DOIUrl":null,"url":null,"abstract":"Experimental parameters of Cd,,Z%Te detectors relevant to nuclear medical imaging are presented and discussed. An image of a thyroid phantom was acquired with an early-stage prototype Cd,JqTe detector array imager using conditions to emulate observations in a human patient and a nuclear medicine imaging parallel-hole collimator. The phantom was filled with a Tc-99m solution. Results were compared with an image obtained from a modern commercial Anger camera under the same conditions. The Cd,-J%Te imager was found to exhibit resolution and contrast at least equal to those of the Anger camera.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1993.701724","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Experimental parameters of Cd,,Z%Te detectors relevant to nuclear medical imaging are presented and discussed. An image of a thyroid phantom was acquired with an early-stage prototype Cd,JqTe detector array imager using conditions to emulate observations in a human patient and a nuclear medicine imaging parallel-hole collimator. The phantom was filled with a Tc-99m solution. Results were compared with an image obtained from a modern commercial Anger camera under the same conditions. The Cd,-J%Te imager was found to exhibit resolution and contrast at least equal to those of the Anger camera.
核医学成像用CdZnTe探测器阵列
介绍并讨论了与核医学成像有关的Cd、Z%Te探测器的实验参数。利用早期原型Cd,JqTe探测器阵列成像仪和核医学成像平行孔准直仪模拟人类患者的观察结果,获得了甲状腺幻像的图像。幻影中充满了Tc-99m溶液。结果与现代商用Anger相机在相同条件下获得的图像进行了比较。Cd,-J%的成像仪被发现显示出分辨率和对比度至少等于那些愤怒的相机。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信