{"title":"Developing a Gold coated Fiber Brag Grating (FBG) sensor to monitor chlorine levels in water","authors":"Summer Dalgamouni, D. Benhaddou, S. Brankovic","doi":"10.1109/IPC53466.2022.9975714","DOIUrl":null,"url":null,"abstract":"Monitoring chlorine levels in water are crucial to prevent health risks in humans. This study investigated designing a sensitive FBG sensor to measure chlorine levels in water in ppm. The overall sensing mechanism provides advantages like; small features, high resolution, and sensing along the whole fiber length; the results were promising, and the sensor provided minimal chlorine levels detection in the water, with a detection range was between (1 -10) ppm, making it sufficient for the study.","PeriodicalId":202839,"journal":{"name":"2022 IEEE Photonics Conference (IPC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Photonics Conference (IPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPC53466.2022.9975714","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Monitoring chlorine levels in water are crucial to prevent health risks in humans. This study investigated designing a sensitive FBG sensor to measure chlorine levels in water in ppm. The overall sensing mechanism provides advantages like; small features, high resolution, and sensing along the whole fiber length; the results were promising, and the sensor provided minimal chlorine levels detection in the water, with a detection range was between (1 -10) ppm, making it sufficient for the study.