A dedicated data acquisition and monitors system for measuring the response times of gas sensors

A. Vasile, S. Setnic, E. Buzoianu
{"title":"A dedicated data acquisition and monitors system for measuring the response times of gas sensors","authors":"A. Vasile, S. Setnic, E. Buzoianu","doi":"10.1109/SMICND.1998.733829","DOIUrl":null,"url":null,"abstract":"For measuring the gas sensors response and recovery times a complex system was built. The gas concentration under the steady-state conditions is varied through a dilution system. We have demonstrated the feasibility of using an interactive program and an electronic system to study the response speed for gas sensors in multiple gas mixture. The system is generally enough to be extended to measurable parameters specific for gas sensors (EMF, R,I).","PeriodicalId":406922,"journal":{"name":"1998 International Semiconductor Conference. CAS'98 Proceedings (Cat. No.98TH8351)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1998 International Semiconductor Conference. CAS'98 Proceedings (Cat. No.98TH8351)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SMICND.1998.733829","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

For measuring the gas sensors response and recovery times a complex system was built. The gas concentration under the steady-state conditions is varied through a dilution system. We have demonstrated the feasibility of using an interactive program and an electronic system to study the response speed for gas sensors in multiple gas mixture. The system is generally enough to be extended to measurable parameters specific for gas sensors (EMF, R,I).
用于测量气体传感器响应时间的专用数据采集和监控系统
为了测量气体传感器的响应和恢复时间,建立了一个复杂的系统。在稳态条件下,气体浓度通过稀释系统变化。我们已经证明了使用交互式程序和电子系统来研究多种气体混合物中气体传感器响应速度的可行性。该系统一般足以扩展到气体传感器的可测量参数(EMF, R,I)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信