Is accurate recording of the surface Laplacian feasible?

D. Geselowitz, J. Ferrara
{"title":"Is accurate recording of the surface Laplacian feasible?","authors":"D. Geselowitz, J. Ferrara","doi":"10.1109/ICBEM.1998.666366","DOIUrl":null,"url":null,"abstract":"Experimental and model studies were performed to measure the surface Laplacian using a rectangular finite difference approximation. The experimental approach used 10 normal subjects with two sites on the torso. Electrode spacing was 2 cm. The surface Laplacian is theoretically independent of rotation of the electrode array. The data showed considerable variation with rotation. Model studies employed a realistic 23 dipole source. A spherical volume conductor showed invariance with rotation, as anticipated theoretically. A realistic torso, however, showed variation with rotation, although a not as severe as that measured. The average signal to noise ratio was 3.3 and 2.5 at the two sites. These results raise serious questions about the practical ability to measure the surface Laplacian on the torso.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBEM.1998.666366","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Experimental and model studies were performed to measure the surface Laplacian using a rectangular finite difference approximation. The experimental approach used 10 normal subjects with two sites on the torso. Electrode spacing was 2 cm. The surface Laplacian is theoretically independent of rotation of the electrode array. The data showed considerable variation with rotation. Model studies employed a realistic 23 dipole source. A spherical volume conductor showed invariance with rotation, as anticipated theoretically. A realistic torso, however, showed variation with rotation, although a not as severe as that measured. The average signal to noise ratio was 3.3 and 2.5 at the two sites. These results raise serious questions about the practical ability to measure the surface Laplacian on the torso.
精确记录表面拉普拉斯是否可行?
实验和模型研究进行了测量表面拉普拉斯使用矩形有限差分近似。实验方法采用10名正常受试者,躯干上有两个部位。电极间距为2 cm。表面拉普拉斯量在理论上与电极阵列的旋转无关。数据显示随着旋转有相当大的变化。模型研究采用了一个现实的23偶极子源。球形体积导体表现出随旋转的不变性,正如理论上所预料的那样。然而,真实的躯干随着旋转而变化,尽管没有测量的那么严重。两个站点的平均信噪比分别为3.3和2.5。这些结果对测量躯干表面拉普拉斯函数的实际能力提出了严重的问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信