Assessment Methods of Knee Joint Arthrokinematics: A Review of Literature

A. Norasteh, H. Zarei
{"title":"Assessment Methods of Knee Joint Arthrokinematics: A Review of Literature","authors":"A. Norasteh, H. Zarei","doi":"10.32598/jrosj.8.3.783.1","DOIUrl":null,"url":null,"abstract":"Context: The present study provides an analysis of methods in assessment and measurement of knee arthrokinematic movements. Evidence Acquisition: in this study, an exhaustive review of the methods for assessment of knee joint arthrokinematics is provided. For this, some known databases including Science Direct, PubMed, EMBASE, CINAHL, and Google Scholar, for the period 1985 to February 2020 are explored. Results: After the assessment steps, 14 articles were chosen based on the criteria and objectives of the research; 13 articles in entirety and one as a summary. Through a review of the studies, it was observed that various methods were used in assessment and measurement of the knee joint arthrokinematic movements. In the beginning, focus was on transitional motion in which knee arthrokinematic movements were studied in static state; but with time, knee transitional movement was studied in dynamic state as well. More recent studies scrutinized three main types of arthrokinematics: motion rolling, gliding and spinning. There were also studies that tried to implement tools which required minimum cost and scrutinized the knee arthrokinematic movements without complicated state-of-the-art equipment. All the said equipment were designed with the aim of diagnosis of how the arthrokinematic movements of an injured knee compared to a healthy one. Conclusion: Results of our analysis show that the literature is rich with a variety of instruments for measuring knee arthrokinematic movements. By classifying the instruments, it was found that studies of four different measurement methods including static, dynamic, functional and qualitative have examined the arthrokinematic movements of the knee.","PeriodicalId":286829,"journal":{"name":"Journal of Research in Orthopedic Science","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Research in Orthopedic Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32598/jrosj.8.3.783.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Context: The present study provides an analysis of methods in assessment and measurement of knee arthrokinematic movements. Evidence Acquisition: in this study, an exhaustive review of the methods for assessment of knee joint arthrokinematics is provided. For this, some known databases including Science Direct, PubMed, EMBASE, CINAHL, and Google Scholar, for the period 1985 to February 2020 are explored. Results: After the assessment steps, 14 articles were chosen based on the criteria and objectives of the research; 13 articles in entirety and one as a summary. Through a review of the studies, it was observed that various methods were used in assessment and measurement of the knee joint arthrokinematic movements. In the beginning, focus was on transitional motion in which knee arthrokinematic movements were studied in static state; but with time, knee transitional movement was studied in dynamic state as well. More recent studies scrutinized three main types of arthrokinematics: motion rolling, gliding and spinning. There were also studies that tried to implement tools which required minimum cost and scrutinized the knee arthrokinematic movements without complicated state-of-the-art equipment. All the said equipment were designed with the aim of diagnosis of how the arthrokinematic movements of an injured knee compared to a healthy one. Conclusion: Results of our analysis show that the literature is rich with a variety of instruments for measuring knee arthrokinematic movements. By classifying the instruments, it was found that studies of four different measurement methods including static, dynamic, functional and qualitative have examined the arthrokinematic movements of the knee.
膝关节关节运动学评估方法:文献综述
背景:本研究分析了评估和测量膝关节运动的方法。证据获取:在这项研究中,对评估膝关节关节运动学的方法进行了详尽的回顾。为此,研究了1985年至2020年2月期间的一些已知数据库,包括Science Direct、PubMed、EMBASE、CINAHL和Google Scholar。结果:经过评估步骤,根据研究的标准和目标选择了14篇文章;全文13篇,总结1篇。通过对研究的回顾,我们观察到各种方法被用于评估和测量膝关节的关节运动。一开始着重于过渡运动,在静止状态下研究膝关节的运动学运动;但随着时间的推移,在动态状态下对膝关节的过渡运动也进行了研究。最近的研究仔细研究了三种主要的关节运动学类型:运动滚动、滑动和旋转。也有研究试图使用成本最低的工具,并在没有复杂的先进设备的情况下检查膝关节运动。所有这些设备的设计目的都是为了诊断受伤膝盖与健康膝盖的关节运动情况。结论:我们的分析结果表明,文献中有丰富的各种测量膝关节运动的仪器。通过对仪器进行分类,发现静态、动态、功能和定性四种不同测量方法的研究都检测了膝关节的关节运动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信