The correlation between dose homogeneity index and target volume in intracavitary brachytherapy treatment plans of cervical cancer patients

Gurpreet Kaur, V. Dangwal, Garima Gaur, R. Grover, M. Kang, Sheetal, Simrandeep Singh, P. Garg
{"title":"The correlation between dose homogeneity index and target volume in intracavitary brachytherapy treatment plans of cervical cancer patients","authors":"Gurpreet Kaur, V. Dangwal, Garima Gaur, R. Grover, M. Kang, Sheetal, Simrandeep Singh, P. Garg","doi":"10.4103/jrmt.jrmt_10_22","DOIUrl":null,"url":null,"abstract":"Aim: The aim is to calculate and correlate dose homogeneity index (DHI) with the target volume of intracavitary brachytherapy (ICBT) plans for cervical cancer patients. Introduction: In the case of brachytherapy, the dose distribution is heterogeneous as a very high radiation dose gradient is there in the vicinity of the radiation source. To assess the treatment plans, one of the objective tools is DHI which can give a choice for making a favorable plan with maximum homogeneous coverage of tumor and protects normal tissues at the same time. In this study, DHI was calculated and correlated with clinical target volume. Materials and Methods: Forty-five treatment plans of ICBT of cervical cancer patients were generated. DHI was calculated for all these treatment plans. These treatment plans were divided into six groups according to the volume of clinical targets, and data were analyzed to find out the correlation between DHI and clinical target volume. Results: The minimum, maximum, and mean values of DHI for all the treatment plans were 0.0045, 0.4998, and 0.2389, respectively. The minimum and maximum values of DHI was seen for clinical target volume of 19.99 cc and 37.32 cc, respectively. The volume of the clinical target varied from 15.41 cc to 44.32 cc, with an average value of 30.5 cc. Discussion: The lowest value of DHI was seen in the group having the lowest clinical target volume and the highest DHI was seen in the group having the largest clinical target volume. These observations suggest that homogeneity was worsening as the volume of tumor increases. Conclusion: DHI may be a good indicator to assess the quality of treatment plan during the planning.","PeriodicalId":319549,"journal":{"name":"Journal of Radiation Medicine in the Tropics","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiation Medicine in the Tropics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jrmt.jrmt_10_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The aim is to calculate and correlate dose homogeneity index (DHI) with the target volume of intracavitary brachytherapy (ICBT) plans for cervical cancer patients. Introduction: In the case of brachytherapy, the dose distribution is heterogeneous as a very high radiation dose gradient is there in the vicinity of the radiation source. To assess the treatment plans, one of the objective tools is DHI which can give a choice for making a favorable plan with maximum homogeneous coverage of tumor and protects normal tissues at the same time. In this study, DHI was calculated and correlated with clinical target volume. Materials and Methods: Forty-five treatment plans of ICBT of cervical cancer patients were generated. DHI was calculated for all these treatment plans. These treatment plans were divided into six groups according to the volume of clinical targets, and data were analyzed to find out the correlation between DHI and clinical target volume. Results: The minimum, maximum, and mean values of DHI for all the treatment plans were 0.0045, 0.4998, and 0.2389, respectively. The minimum and maximum values of DHI was seen for clinical target volume of 19.99 cc and 37.32 cc, respectively. The volume of the clinical target varied from 15.41 cc to 44.32 cc, with an average value of 30.5 cc. Discussion: The lowest value of DHI was seen in the group having the lowest clinical target volume and the highest DHI was seen in the group having the largest clinical target volume. These observations suggest that homogeneity was worsening as the volume of tumor increases. Conclusion: DHI may be a good indicator to assess the quality of treatment plan during the planning.
宫颈癌腔内近距离放疗方案中剂量均匀性指数与靶体积的关系
目的:计算宫颈癌腔内近距离放射治疗(ICBT)方案剂量均匀性指数(DHI)与靶体积之间的关系。在近距离放射治疗中,由于辐射源附近存在非常高的辐射剂量梯度,剂量分布是不均匀的。评估治疗方案的客观工具之一是DHI,它可以在最大程度上均匀覆盖肿瘤的同时,保护正常组织,为制定有利的方案提供选择。本研究计算DHI并与临床靶体积相关。材料与方法:生成45例宫颈癌患者ICBT治疗方案。计算所有治疗方案的DHI。将这些治疗方案根据临床靶标量分为6组,分析数据,找出DHI与临床靶标量的相关性。结果:各治疗方案DHI的最小值、最大值和平均值分别为0.0045、0.4998和0.2389。临床靶体积最小值为19.99 cc,最大值为37.32 cc。临床靶区容积从15.41 cc到44.32 cc不等,平均为30.5 cc。讨论:临床靶区容积最小的组DHI值最低,临床靶区容积最大的组DHI值最高。这些观察结果表明,均匀性随着肿瘤体积的增加而恶化。结论:在制定治疗方案时,DHI可作为评价治疗方案质量的良好指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信