{"title":"CRITERIA FOR EVALUATION OF DOSIMETRIC VERIFICATION OF RADIOTHERAPY HIGH-TECH TREATMENT PLANS FOR CANCER PATIENTS","authors":"A. Brynkevich, M. Piatkevich, E. Titovich","doi":"10.46646/sakh-2021-2-252-255","DOIUrl":null,"url":null,"abstract":"To test the effectiveness of the dose delivery system of the treatment plan in intensity modulated radiation therapy, quality assurance systems are used. The main tool for verifying the correspondence between the reference and the estimated dose distribution is Y—indexing. In the process of Y—analysis of individual dose distributions, both point dose values and geometrical offset between the reference and delivered distributions are evaluated. To check the compliance of dose distributions, the concepts of action limits and tolerances are used. The action limits are defined as the total percentage of the estimated value by which deviation of the indicators checked by the quality assurance system is allowed, with a minimal risk of harm to the patient. Tolerances are defined as the boundaries of the magnitude change within which the treatment process is considered to be performed according to the prescribed conditions.","PeriodicalId":385455,"journal":{"name":"SAKHAROV READINGS 2021: ENVIRONMENTAL PROBLEMS OF THE XXI CENTURY Part 2","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SAKHAROV READINGS 2021: ENVIRONMENTAL PROBLEMS OF THE XXI CENTURY Part 2","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46646/sakh-2021-2-252-255","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To test the effectiveness of the dose delivery system of the treatment plan in intensity modulated radiation therapy, quality assurance systems are used. The main tool for verifying the correspondence between the reference and the estimated dose distribution is Y—indexing. In the process of Y—analysis of individual dose distributions, both point dose values and geometrical offset between the reference and delivered distributions are evaluated. To check the compliance of dose distributions, the concepts of action limits and tolerances are used. The action limits are defined as the total percentage of the estimated value by which deviation of the indicators checked by the quality assurance system is allowed, with a minimal risk of harm to the patient. Tolerances are defined as the boundaries of the magnitude change within which the treatment process is considered to be performed according to the prescribed conditions.
癌症患者放疗高科技治疗方案剂量学验证评价标准
为了测试治疗计划的剂量传递系统在调强放射治疗中的有效性,使用了质量保证系统。验证参考剂量分布与估计剂量分布是否对应的主要工具是y标度。在个体剂量分布的y分析过程中,评估了点剂量值和参考分布与交付分布之间的几何偏移。为了检查剂量分布的顺应性,使用了作用限值和容许量的概念。作用限值定义为在对患者造成最小伤害风险的情况下,允许质量保证体系检查的指标偏差占估计值的总百分比。公差被定义为幅度变化的边界,在此范围内,处理过程被认为是根据规定的条件进行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信