Investigation of Limitations in Active Damping Control of LCL Filter Resonance using Inverter Side Current Feedback in Grid Connected Voltage Source Converter

Satyanarayana Muddasani, A. V. Ravi Teja
{"title":"Investigation of Limitations in Active Damping Control of LCL Filter Resonance using Inverter Side Current Feedback in Grid Connected Voltage Source Converter","authors":"Satyanarayana Muddasani, A. V. Ravi Teja","doi":"10.1109/TPEC51183.2021.9384938","DOIUrl":null,"url":null,"abstract":"This paper investigates the active damping of LCL filter resonance in a grid connected voltage source inverter. The active damping realized using feedback of inverter side current is considered for analysis. A detailed study showing suitable choice of resistor required for resonance damping in case of the passive and active damping methods is presented. An explicit study showing the limitations of active damping over passive damping for a chosen Switching and resonance frequencies has carried out. The proposed work is simulated using MATLAB/Simulink for the resonance frequency of 1.4kHz and switching frequency of 10KHz. Typical results are reported and analyzed. It is observed from results that the virtual resistor introduced using active damping technique is unlike to the passive damping after a point of Rd values. This issue can be resolved by choosing controller bandwidth adaptive to the changes present in value of virtual resistor.","PeriodicalId":354018,"journal":{"name":"2021 IEEE Texas Power and Energy Conference (TPEC)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Texas Power and Energy Conference (TPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TPEC51183.2021.9384938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper investigates the active damping of LCL filter resonance in a grid connected voltage source inverter. The active damping realized using feedback of inverter side current is considered for analysis. A detailed study showing suitable choice of resistor required for resonance damping in case of the passive and active damping methods is presented. An explicit study showing the limitations of active damping over passive damping for a chosen Switching and resonance frequencies has carried out. The proposed work is simulated using MATLAB/Simulink for the resonance frequency of 1.4kHz and switching frequency of 10KHz. Typical results are reported and analyzed. It is observed from results that the virtual resistor introduced using active damping technique is unlike to the passive damping after a point of Rd values. This issue can be resolved by choosing controller bandwidth adaptive to the changes present in value of virtual resistor.
并网电压源变换器逆变侧电流反馈对LCL滤波器谐振主动阻尼控制的局限性研究
本文研究了一种并网电压源逆变器中LCL滤波器谐振的主动阻尼。分析了利用逆变器侧电流反馈实现的主动阻尼。详细研究了在被动和主动阻尼两种情况下,谐振阻尼所需电阻的选择。一项明确的研究表明,在选定的开关和谐振频率下,主动阻尼比被动阻尼的局限性已经进行。在谐振频率为1.4kHz、开关频率为10KHz的条件下,利用MATLAB/Simulink对所提出的工作进行了仿真。对典型结果进行了报告和分析。从结果中可以看出,采用主动阻尼技术引入的虚电阻不同于在一个Rd值点后的被动阻尼。这个问题可以通过选择适应虚电阻值变化的控制器带宽来解决。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信