Accuracy Assessment Of Bracket Placement By Indirect Bonding Technique Using Three-Dimensional Imaging And Steroelithographic Printing Technique

Ahmed El Rashidy, W. Refai
{"title":"Accuracy Assessment Of Bracket Placement By Indirect Bonding Technique Using Three-Dimensional Imaging And Steroelithographic Printing Technique","authors":"Ahmed El Rashidy, W. Refai","doi":"10.21608/eos.2023.202537.1067","DOIUrl":null,"url":null,"abstract":"Objective : this clinical trial was designed to assess the accuracy of bracket placement by indirect bonding by using three dimensional imaging and steroelithographic printing technique. Materials and methods: a clinical trial was held on ten patients were planned to be bonded by full digital indirect bonding tray for upper arch. Intra- oral scanning of each patient was held after indirect bonding to get STL file for evaluation. Vertical brackets positions of total 120 brackets bonded were measured and evaluated. Intra class correlation and Bland Altman plot test were used to assess the accuracy of vertical bracket position of the full digital transfer tray. Results: considering the whole units (120 units), excellent reliability and internal consistency (ICC>0.9) with p value < 0.001* with High level of agreement P value =0.089. For lateral incisors, canines and premolar groups, there was good reliability (0.9> ICC>0.75) with high level of agreement with p value = 0.068, 0.706 and 0.794 in order. An acceptable reliability (0.75>ICC>0.5) was found in central incisors and molars groups. The central incisors and molars groups exhibited a proportional bias in agreement test with by P value 0.047 *, 0.019* in order which is clinically insignificant. There was no statistical difference between the mean differences of the five groups P value = 0.185 .with range of mean differences (0.002:0.175) mm which was not clinical significant. Conclusion: this protocol transferred the planed vertical brackets position from the virtual setup to the patient was generally highly accurate and reliable technique.","PeriodicalId":305086,"journal":{"name":"Egyptian Orthodontic Journal","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Orthodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/eos.2023.202537.1067","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective : this clinical trial was designed to assess the accuracy of bracket placement by indirect bonding by using three dimensional imaging and steroelithographic printing technique. Materials and methods: a clinical trial was held on ten patients were planned to be bonded by full digital indirect bonding tray for upper arch. Intra- oral scanning of each patient was held after indirect bonding to get STL file for evaluation. Vertical brackets positions of total 120 brackets bonded were measured and evaluated. Intra class correlation and Bland Altman plot test were used to assess the accuracy of vertical bracket position of the full digital transfer tray. Results: considering the whole units (120 units), excellent reliability and internal consistency (ICC>0.9) with p value < 0.001* with High level of agreement P value =0.089. For lateral incisors, canines and premolar groups, there was good reliability (0.9> ICC>0.75) with high level of agreement with p value = 0.068, 0.706 and 0.794 in order. An acceptable reliability (0.75>ICC>0.5) was found in central incisors and molars groups. The central incisors and molars groups exhibited a proportional bias in agreement test with by P value 0.047 *, 0.019* in order which is clinically insignificant. There was no statistical difference between the mean differences of the five groups P value = 0.185 .with range of mean differences (0.002:0.175) mm which was not clinical significant. Conclusion: this protocol transferred the planed vertical brackets position from the virtual setup to the patient was generally highly accurate and reliable technique.
利用三维成像和立体光刻技术间接粘接支架放置精度评价
目的:本临床试验旨在评估采用三维成像和立体印刷技术间接粘接支架放置的准确性。材料与方法:对10例患者进行全数字上弓间接粘接托盘的临床试验。每位患者间接粘接后进行口腔内扫描,获取STL文件进行评估。测量和评估了共120个粘接支架的垂直支架位置。采用类内相关和Bland Altman图检验评估全数字传递托盘垂直支架位置的准确性。结果:考虑整个单位(120个单位),具有良好的信度和内部一致性(ICC>0.9), p值< 0.001*,高水平一致性p值=0.089。侧切牙组、犬齿组和前磨牙组的可靠性较好(0.9> ICC>0.75),一致性较高,p值依次为0.068、0.706和0.794。中切牙组和磨牙组的ICC值均为0.75> 0.5,可靠性可接受。中切牙组和磨牙组在一致性检验中存在比例偏倚,P值依次为0.047 *、0.019*,临床差异不显著。五组间平均差异无统计学意义(P值= 0.185),平均差异范围(0.002:0.175)mm,无临床意义。结论:该方案将平面垂直托槽位置从虚拟装置转移到患者身上,总体上是高度准确可靠的技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信