{"title":"Theoretical and practical comparison of shielding wire's position in 132 kV and 500 kV transmission lines in Argentina","authors":"Héctor L. Soibelzon, Julieta Z. Vernieri","doi":"10.1109/SIPDA.2011.6088449","DOIUrl":null,"url":null,"abstract":"The aim of this paper is to analise theoretical methods of shielding protection techniques in transmission lines and their correspondance with practical use in Argentina. The frequent practice of shielding wire positioning observed in the field is compared with the position obtained by applying classic and modern methods. The paper concludes that the “Electrogeometric Model” (EGM) matches pretty well with practical use in 500 kV power lines, while this method leads to unpractical and uneconomic results in 132 kV lines.","PeriodicalId":277573,"journal":{"name":"2011 International Symposium on Lightning Protection","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Symposium on Lightning Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2011.6088449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this paper is to analise theoretical methods of shielding protection techniques in transmission lines and their correspondance with practical use in Argentina. The frequent practice of shielding wire positioning observed in the field is compared with the position obtained by applying classic and modern methods. The paper concludes that the “Electrogeometric Model” (EGM) matches pretty well with practical use in 500 kV power lines, while this method leads to unpractical and uneconomic results in 132 kV lines.
阿根廷132kv与500kv输电线路屏蔽线位置的理论与实践比较
本文旨在分析阿根廷输电线路屏蔽保护技术的理论方法及其与实际应用的对应关系。将现场观察到的频繁的屏蔽线定位实践与应用经典和现代方法所获得的位置进行了比较。结论认为,“电几何模型”(EGM)在500kv输电线路中与实际应用吻合较好,而在132kv输电线路中则不实用、不经济。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信