{"title":"Development DAQ module for intelligent sensor system","authors":"R. Kochan, V. Kochan, A. Sachenko, V. Turchenko","doi":"10.1109/SFICON.2002.1159813","DOIUrl":null,"url":null,"abstract":"In this paper a precision single-board, 8 channels; 24 bit sigma-delta ADC with an on-line remote reprogramming mode, forming a data acquisition module (DAQ), is described. The results of experimental research of the noise immunity of the developed ADC in real (industrial) measurement conditions are presented. The results of experimental research on the prototype in the same measurement conditions are also considered.","PeriodicalId":294424,"journal":{"name":"2nd ISA/IEEE Sensors for Industry Conference,","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2nd ISA/IEEE Sensors for Industry Conference,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SFICON.2002.1159813","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
In this paper a precision single-board, 8 channels; 24 bit sigma-delta ADC with an on-line remote reprogramming mode, forming a data acquisition module (DAQ), is described. The results of experimental research of the noise immunity of the developed ADC in real (industrial) measurement conditions are presented. The results of experimental research on the prototype in the same measurement conditions are also considered.