Mobile laser photoacoustic spectrometer for multicomponent trace-gas monitoring based on CO/sub 2/- and quantum-cascade lasers as pump sources

M. Nagele, D. Hofstetter, J. Faist, M. Sigrist
{"title":"Mobile laser photoacoustic spectrometer for multicomponent trace-gas monitoring based on CO/sub 2/- and quantum-cascade lasers as pump sources","authors":"M. Nagele, D. Hofstetter, J. Faist, M. Sigrist","doi":"10.1109/CLEOE.2000.909779","DOIUrl":null,"url":null,"abstract":"Summary form only given. The development and application of a mobile laser-photoacoustic spectrometer for in-situ multicomponent monitoring of trace gases in different environments is reported. Sub-ppbV (<10/sup -9/ per volume)-concentrations can be measured with a novel resonant multipass photoacoustic cell. For ethene (C/sub 2/H/sub 4/) buffered in synthetic air a minimum detection limit of 70 pptV (70/spl times/10/sup -12/ per volume) is achieved with a line-tunable CO/sub 2/-laser as pump source corresponding to a minimum measurable absorption coefficient /spl alpha//sub min/=2/spl times/10/sup -9/ cm/sup -1/ for a signal-to-noise ratio of 3. The multicomponent capability of the system is demonstrated with continuous sequential measurements of gases such as ethene, methanol, and ethanol of air from a fruit storage chamber.","PeriodicalId":250878,"journal":{"name":"Conference Digest. 2000 Conference on Lasers and Electro-Optics Europe (Cat. No.00TH8505)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Digest. 2000 Conference on Lasers and Electro-Optics Europe (Cat. No.00TH8505)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CLEOE.2000.909779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Summary form only given. The development and application of a mobile laser-photoacoustic spectrometer for in-situ multicomponent monitoring of trace gases in different environments is reported. Sub-ppbV (<10/sup -9/ per volume)-concentrations can be measured with a novel resonant multipass photoacoustic cell. For ethene (C/sub 2/H/sub 4/) buffered in synthetic air a minimum detection limit of 70 pptV (70/spl times/10/sup -12/ per volume) is achieved with a line-tunable CO/sub 2/-laser as pump source corresponding to a minimum measurable absorption coefficient /spl alpha//sub min/=2/spl times/10/sup -9/ cm/sup -1/ for a signal-to-noise ratio of 3. The multicomponent capability of the system is demonstrated with continuous sequential measurements of gases such as ethene, methanol, and ethanol of air from a fruit storage chamber.
基于CO/ sub2 /-和量子级联激光器作为泵浦源的多组分痕量气体监测移动激光光声光谱仪
只提供摘要形式。报道了可移动激光光声光谱仪的研制及其在不同环境下多组分痕量气体原位监测的应用。亚ppbv (<10/sup -9/每体积)浓度可以用一种新型共振多通光声电池测量。对于合成空气中缓冲的乙烯(C/sub 2/H/sub 4/),采用可线调谐CO/sub 2/-激光器作为泵浦源,达到70 pptV (70/spl倍/10/sup -12/每体积)的最小检测极限,对应于最小可测量吸收系数/spl alpha//sub min/=2/spl倍/10/sup -9/ cm/sup -1/,信噪比为3。该系统的多组分能力是通过连续连续的气体测量,如乙烯,甲醇和乙醇的空气从水果储存室证明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信