{"title":"New Micropotentionstat for Measurement Responses from Thick-Film Sensors","authors":"P. Steffan, R. Vrba","doi":"10.1109/ICONS.2007.37","DOIUrl":null,"url":null,"abstract":"The new solution of the amperometric sensor measurement is given. It solves the problem of measurement of low currents (in order of nA) from electrochemical biosensors. However the sensitivity of integrated measurement system, which process output currents from biosensor, has to be in order of pA. There are leakage currents and noise constraints which could be avoided by on chip solution. The on-chip solution allows direct chip connection on the basic ceramic plate of biosensors. It means the idea is similar to hybrid integrated circuit. Main advantage of this solution is separating sensitive low potential and low current ASIC electronics placed just on the TFT sensor from control and supply electronics of portable device. Additional advantages of the sensors fabricated using TFT are low cost, small dimensions, good reproducibility, chemical, mechanical and electrical properties of electrodes and well accessible and ecological fabrication process.","PeriodicalId":355435,"journal":{"name":"Second International Conference on Systems (ICONS'07)","volume":"155 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Second International Conference on Systems (ICONS'07)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICONS.2007.37","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The new solution of the amperometric sensor measurement is given. It solves the problem of measurement of low currents (in order of nA) from electrochemical biosensors. However the sensitivity of integrated measurement system, which process output currents from biosensor, has to be in order of pA. There are leakage currents and noise constraints which could be avoided by on chip solution. The on-chip solution allows direct chip connection on the basic ceramic plate of biosensors. It means the idea is similar to hybrid integrated circuit. Main advantage of this solution is separating sensitive low potential and low current ASIC electronics placed just on the TFT sensor from control and supply electronics of portable device. Additional advantages of the sensors fabricated using TFT are low cost, small dimensions, good reproducibility, chemical, mechanical and electrical properties of electrodes and well accessible and ecological fabrication process.