Online Insulation Fault Detection of Stator Winding of Induction Motor based on a Non-Intrusive Impedance Extraction Technique

Zhenyu Zhao, K. See, E. Chua, A. Narayanan, Arjuna Weerasinghe, Zhenning Yang, K. Tan
{"title":"Online Insulation Fault Detection of Stator Winding of Induction Motor based on a Non-Intrusive Impedance Extraction Technique","authors":"Zhenyu Zhao, K. See, E. Chua, A. Narayanan, Arjuna Weerasinghe, Zhenning Yang, K. Tan","doi":"10.1109/ICIRT.2018.8641627","DOIUrl":null,"url":null,"abstract":"The induction motor has been widely used in a variety of industrial applications and is usually critical to the safe and reliable operation of the entire system. Since the insulation faults of the stator winding have accounted for a large proportion of faults in various induction motors, the technique to detect the early-stage insulation faults of the stator winding will be very useful as a timely maintenance scheme can be conducted for preventing the faults proliferation, thereby, reducing the safety risks, motor downtime, and the cost from maintenance and downtime. Therefore, this paper describes an online stator winding insulation faults detection method based on a non-intrusive impedance extraction technique. Experimental results show that the proposed method has the ability to detect the early-stage insulation faults of the stator winding before a catastrophic failure occurs with a simple onsite implementation and low safety hazards.","PeriodicalId":202415,"journal":{"name":"2018 International Conference on Intelligent Rail Transportation (ICIRT)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Intelligent Rail Transportation (ICIRT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIRT.2018.8641627","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

The induction motor has been widely used in a variety of industrial applications and is usually critical to the safe and reliable operation of the entire system. Since the insulation faults of the stator winding have accounted for a large proportion of faults in various induction motors, the technique to detect the early-stage insulation faults of the stator winding will be very useful as a timely maintenance scheme can be conducted for preventing the faults proliferation, thereby, reducing the safety risks, motor downtime, and the cost from maintenance and downtime. Therefore, this paper describes an online stator winding insulation faults detection method based on a non-intrusive impedance extraction technique. Experimental results show that the proposed method has the ability to detect the early-stage insulation faults of the stator winding before a catastrophic failure occurs with a simple onsite implementation and low safety hazards.
基于非侵入式阻抗提取技术的异步电动机定子绕组绝缘故障在线检测
感应电机已广泛应用于各种工业应用中,通常对整个系统的安全可靠运行至关重要。在各类异步电动机中,定子绕组绝缘故障在故障中所占的比例很大,因此,及早检测定子绕组绝缘故障的技术将非常有用,可以及时制定检修方案,防止故障扩散,从而减少安全风险,减少电机停机时间,降低维修停机成本。因此,本文提出了一种基于非侵入式阻抗提取技术的定子绕组绝缘故障在线检测方法。实验结果表明,该方法能够在发生灾难性故障前检测到定子绕组的早期绝缘故障,现场实现简单,安全隐患小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信