H. van Breen, E. Gulski, J. Smit, H. Verhaart, W. de Leeuw, M. Krieg-Wezelenburg
{"title":"Standardizing the interpretation of on-line VHF PD measurements on turbo generators","authors":"H. van Breen, E. Gulski, J. Smit, H. Verhaart, W. de Leeuw, M. Krieg-Wezelenburg","doi":"10.1109/EEIC.2001.965711","DOIUrl":null,"url":null,"abstract":"Presently, an expert is needed to interpret the results of an on-line VHF PD measurement on a turbogenerator. And even then, different experts will interpret the results differently. Standardization of the interpretation of online VHF PD measurements is needed before a generator operator can use online VHF PD measurements in his or her maintenance program. This paper presents such a method for interpreting the results of on-line VHF PD measurements performed on turbogenerators. Using the interpretation method, the stator insulation system is classified into one of the following categories: \"insulation system ok\", \"insulation system ok?\", \"insulation system not ok?\" or \"insulation system not ok\". discharges. The presented method is currently used for the interpretation of on-line VHF PD measurements on turbogenerators throughout the Netherlands.","PeriodicalId":228071,"journal":{"name":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.2001.965711","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Presently, an expert is needed to interpret the results of an on-line VHF PD measurement on a turbogenerator. And even then, different experts will interpret the results differently. Standardization of the interpretation of online VHF PD measurements is needed before a generator operator can use online VHF PD measurements in his or her maintenance program. This paper presents such a method for interpreting the results of on-line VHF PD measurements performed on turbogenerators. Using the interpretation method, the stator insulation system is classified into one of the following categories: "insulation system ok", "insulation system ok?", "insulation system not ok?" or "insulation system not ok". discharges. The presented method is currently used for the interpretation of on-line VHF PD measurements on turbogenerators throughout the Netherlands.