{"title":"A study on the response of 2D ion chamber array detector for VMAT delivery","authors":"S Kumar, A. George","doi":"10.15406/IJRRT.2018.05.00172","DOIUrl":null,"url":null,"abstract":"Purpose This study aims to evaluate the response of D ion chamber array detector for VMAT delivery Methods D array ionization chamber equipped with ionization chambers uniformly arranged in a times matrix with an active times cm was used for the study An Octagonal shaped phantom Octavius Phantom with a central cavity is used to insert the D ion chamber array All measurements were done with a linear accelerator The plans that are already being verified has been selected for studying the response of D array Results This study shows that the response of the D array gets reduced as compared to early quality assured plans Plans were analyzed using the Gamma analysis method The results show a variation up to comparing earlier plans Conclusion The response of the D array gets reduced while compared with earlier quality assured plans","PeriodicalId":214028,"journal":{"name":"International Journal of Radiology & Radiation Therapy","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Radiology & Radiation Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15406/IJRRT.2018.05.00172","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Purpose This study aims to evaluate the response of D ion chamber array detector for VMAT delivery Methods D array ionization chamber equipped with ionization chambers uniformly arranged in a times matrix with an active times cm was used for the study An Octagonal shaped phantom Octavius Phantom with a central cavity is used to insert the D ion chamber array All measurements were done with a linear accelerator The plans that are already being verified has been selected for studying the response of D array Results This study shows that the response of the D array gets reduced as compared to early quality assured plans Plans were analyzed using the Gamma analysis method The results show a variation up to comparing earlier plans Conclusion The response of the D array gets reduced while compared with earlier quality assured plans