Qualitative conditional assessment of human limb using force masking technique with a strain gauge setup

Avisek Naug, Spandan Basu, Arghya Bhattacharya, K. Sanyal
{"title":"Qualitative conditional assessment of human limb using force masking technique with a strain gauge setup","authors":"Avisek Naug, Spandan Basu, Arghya Bhattacharya, K. Sanyal","doi":"10.1109/CMI.2016.7413751","DOIUrl":null,"url":null,"abstract":"This The M curves, force vs. phase curves for gait analysis, are utilized for obtaining variation of voltage output during different stages of the gait cycle. The proposed method in this paper suggests a novel technique by calibration of the voltage and draws an inference on the health of human limb. The linearized calibration curve of the low hysteresis measuring instrument, is taken to our advantage in this measurement technique. An equivalent interpretation is arrived at from the voltage variation pattern analogous (proportional) to the load pattern. Ultimately comparative condition monitoring is performed using the voltage level as the new parameter to differentiate between a healthy and an unhealthy limb.","PeriodicalId":244262,"journal":{"name":"2016 IEEE First International Conference on Control, Measurement and Instrumentation (CMI)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE First International Conference on Control, Measurement and Instrumentation (CMI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CMI.2016.7413751","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This The M curves, force vs. phase curves for gait analysis, are utilized for obtaining variation of voltage output during different stages of the gait cycle. The proposed method in this paper suggests a novel technique by calibration of the voltage and draws an inference on the health of human limb. The linearized calibration curve of the low hysteresis measuring instrument, is taken to our advantage in this measurement technique. An equivalent interpretation is arrived at from the voltage variation pattern analogous (proportional) to the load pattern. Ultimately comparative condition monitoring is performed using the voltage level as the new parameter to differentiate between a healthy and an unhealthy limb.
利用力掩蔽技术和应变计装置对人体肢体进行定性条件评估
M曲线,即用于步态分析的力与相位曲线,用于获得步态周期不同阶段电压输出的变化。本文提出了一种通过电压标定的新方法,并对人体肢体的健康状况进行了推断。低迟滞测量仪的线性化校准曲线在该测量技术中发挥了优势。从与负荷模式相似(成比例)的电压变化模式中得到等效解释。最后,使用电压电平作为新参数进行比较状态监测,以区分健康和不健康的肢体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信