{"title":"Undervoltage Load Shedding","authors":"C. Mozina","doi":"10.1109/CPRE.2007.359889","DOIUrl":null,"url":null,"abstract":"This paper discusses why voltage as well as frequency load shedding may be necessary to prevent major system blackouts. This paper explores the nature of recent power system blackouts and explains why voltage collapse is the leading edge indicator of impending power system problems. It also discusses the design and security issues that need to be addressed in the design of an undervoltage load shedding (UVLS) scheme and why relying on underfrequency load shedding (UFLS) may be \"too little, too late.\" The paper addresses the current level of UVLS on utility systems as well as current NERC (North American Electric Reliability Council) pronouncements on the subject","PeriodicalId":438320,"journal":{"name":"2007 60th Annual Conference for Protective Relay Engineers","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"60","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 60th Annual Conference for Protective Relay Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2007.359889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 60

Abstract

This paper discusses why voltage as well as frequency load shedding may be necessary to prevent major system blackouts. This paper explores the nature of recent power system blackouts and explains why voltage collapse is the leading edge indicator of impending power system problems. It also discusses the design and security issues that need to be addressed in the design of an undervoltage load shedding (UVLS) scheme and why relying on underfrequency load shedding (UFLS) may be "too little, too late." The paper addresses the current level of UVLS on utility systems as well as current NERC (North American Electric Reliability Council) pronouncements on the subject
欠压减载
本文讨论了为什么电压和频率减载可能是必要的,以防止主要的系统停电。本文探讨了近年来电力系统停电的性质,并解释了为什么电压崩溃是即将出现的电力系统问题的前沿指标。它还讨论了欠压减载(UVLS)方案设计中需要解决的设计和安全问题,以及为什么依赖低频减载(UFLS)可能“太少,太迟”。本文讨论了公用事业系统中UVLS的当前水平以及当前NERC(北美电力可靠性委员会)关于该主题的声明
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信