{"title":"A polyethylene liner dissociation case report in depuy pinnacle cup. An impingement problem?","authors":"Alvaro Ayora, G. González, C. Fernandez","doi":"10.5455/aces.20190318055641","DOIUrl":null,"url":null,"abstract":"The modular components facilitate joint replacement surgery but are associated with potential complications not present in the previous components. We present a case of polyethylene dissociation due to rupture of the anti-rotational blocks in a total hip prosthesis two years after surgery. We think about the possible causes and risk factors. Despite its low incidence, the dissociation between polyethylene and the acetabular cup is a catastrophic complication. The femoroacetabular impingement seems to play a key role.","PeriodicalId":371099,"journal":{"name":"Archives of Clinical and Experimental Surgery (ACES)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Clinical and Experimental Surgery (ACES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/aces.20190318055641","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The modular components facilitate joint replacement surgery but are associated with potential complications not present in the previous components. We present a case of polyethylene dissociation due to rupture of the anti-rotational blocks in a total hip prosthesis two years after surgery. We think about the possible causes and risk factors. Despite its low incidence, the dissociation between polyethylene and the acetabular cup is a catastrophic complication. The femoroacetabular impingement seems to play a key role.
副品杯聚乙烯衬垫游离一例报告。撞击问题?
模块化组件促进关节置换手术,但与先前组件不存在的潜在并发症相关。我们提出一例聚乙烯解离,由于破裂的反旋转块在全髋关节假体手术后两年。我们考虑可能的原因和风险因素。尽管发生率低,但聚乙烯与髋臼杯之间的分离是一种灾难性的并发症。股髋臼撞击似乎起了关键作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信