{"title":"A New Methodology For Vienna Rectifier Rating And Controller Tuning Based on Control Saturation Analysis: Experimental Validation","authors":"N. Youssef, K. Al-haddad, H. Kanaan","doi":"10.1109/ISIE.2006.295665","DOIUrl":null,"url":null,"abstract":"The proposed paper aims to analyse the control saturation phenomenon and its influence on the steady state converter performance. This analysis is performed for two main targets: 1) rating AC line inductors, while fulfilling the compromise between a minimal value required to limit main currents ripple at used switching frequency, and a maximal value that maintains the current modulation capability and consequently limits the control saturation phenomenon, 2) tuning the digital controllers parameters, in order to reduce control saturation on the one hand, and ensure low total harmonic distortion (THD), unity power factor (PF) and regulated split DC bus voltages on the other hand. The obtained results clearly show a fundamental dependency between the saturation angle, voltage unbalance controller parameters, and both line inductors size and required output load power","PeriodicalId":296467,"journal":{"name":"2006 IEEE International Symposium on Industrial Electronics","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Symposium on Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2006.295665","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The proposed paper aims to analyse the control saturation phenomenon and its influence on the steady state converter performance. This analysis is performed for two main targets: 1) rating AC line inductors, while fulfilling the compromise between a minimal value required to limit main currents ripple at used switching frequency, and a maximal value that maintains the current modulation capability and consequently limits the control saturation phenomenon, 2) tuning the digital controllers parameters, in order to reduce control saturation on the one hand, and ensure low total harmonic distortion (THD), unity power factor (PF) and regulated split DC bus voltages on the other hand. The obtained results clearly show a fundamental dependency between the saturation angle, voltage unbalance controller parameters, and both line inductors size and required output load power