A New Methodology For Vienna Rectifier Rating And Controller Tuning Based on Control Saturation Analysis: Experimental Validation

N. Youssef, K. Al-haddad, H. Kanaan
{"title":"A New Methodology For Vienna Rectifier Rating And Controller Tuning Based on Control Saturation Analysis: Experimental Validation","authors":"N. Youssef, K. Al-haddad, H. Kanaan","doi":"10.1109/ISIE.2006.295665","DOIUrl":null,"url":null,"abstract":"The proposed paper aims to analyse the control saturation phenomenon and its influence on the steady state converter performance. This analysis is performed for two main targets: 1) rating AC line inductors, while fulfilling the compromise between a minimal value required to limit main currents ripple at used switching frequency, and a maximal value that maintains the current modulation capability and consequently limits the control saturation phenomenon, 2) tuning the digital controllers parameters, in order to reduce control saturation on the one hand, and ensure low total harmonic distortion (THD), unity power factor (PF) and regulated split DC bus voltages on the other hand. The obtained results clearly show a fundamental dependency between the saturation angle, voltage unbalance controller parameters, and both line inductors size and required output load power","PeriodicalId":296467,"journal":{"name":"2006 IEEE International Symposium on Industrial Electronics","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Symposium on Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2006.295665","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The proposed paper aims to analyse the control saturation phenomenon and its influence on the steady state converter performance. This analysis is performed for two main targets: 1) rating AC line inductors, while fulfilling the compromise between a minimal value required to limit main currents ripple at used switching frequency, and a maximal value that maintains the current modulation capability and consequently limits the control saturation phenomenon, 2) tuning the digital controllers parameters, in order to reduce control saturation on the one hand, and ensure low total harmonic distortion (THD), unity power factor (PF) and regulated split DC bus voltages on the other hand. The obtained results clearly show a fundamental dependency between the saturation angle, voltage unbalance controller parameters, and both line inductors size and required output load power
基于控制饱和分析的维也纳整流器额定值和控制器整定新方法:实验验证
本文旨在分析控制饱和现象及其对稳态变换器性能的影响。该分析主要针对两个目标进行:1)对交流线路电感进行额定值,同时满足在使用的开关频率下限制主电流纹波所需的最小值与保持电流调制能力从而限制控制饱和现象的最大值之间的折衷;2)调整数字控制器参数,一方面降低控制饱和,并确保低总谐波失真(THD);统一功率因数(PF)和稳压分路直流母线电压。得到的结果清楚地表明,饱和角、电压不平衡控制器参数、线路电感尺寸和所需输出负载功率之间存在基本依赖关系
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信