{"title":"COMPARISON OF CALCULATION METHODS FOR SHEET PILING","authors":"W. Kosmala-Kot, J. Selejdak","doi":"10.17512/znb.2020.1.13","DOIUrl":null,"url":null,"abstract":"The main aim of this paper is to present the results of the influence comparison of biocides on hot water polypropylene pipes as a part of a longtime investigation on the sustainable and safety of buildings. There are a lot of guidelines that have linked water distribution systems as an infection source and methods on how to eliminate Legionella from water systems. The presence of bacteria in the technical systems of buildings causes contamination, which may be very dangerous if there are good conditions for multiplication. The basic point is the occurrence of biofilms on the walls of distribution pipes as well as material impact. The investigation in the targeted hospital brings together interesting results from a combination of technical solutions and the dosing of biocides and their effect on the inner surface of pipes.","PeriodicalId":354926,"journal":{"name":"Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17512/znb.2020.1.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The main aim of this paper is to present the results of the influence comparison of biocides on hot water polypropylene pipes as a part of a longtime investigation on the sustainable and safety of buildings. There are a lot of guidelines that have linked water distribution systems as an infection source and methods on how to eliminate Legionella from water systems. The presence of bacteria in the technical systems of buildings causes contamination, which may be very dangerous if there are good conditions for multiplication. The basic point is the occurrence of biofilms on the walls of distribution pipes as well as material impact. The investigation in the targeted hospital brings together interesting results from a combination of technical solutions and the dosing of biocides and their effect on the inner surface of pipes.