Auscultation based stethoscopic diagnostic device for cardiac murmur identification

D. Kasun Prasanga, A. Abeykoon, S. Prasad, L. Udawatta
{"title":"Auscultation based stethoscopic diagnostic device for cardiac murmur identification","authors":"D. Kasun Prasanga, A. Abeykoon, S. Prasad, L. Udawatta","doi":"10.1109/ICIT.2011.5754404","DOIUrl":null,"url":null,"abstract":"In a healthy heart, there is no any abnormal blood flow takes place inside, in addition to the usual blood circulating pattern. However when the valves or tissues inside the heart are in diseased conditions, this usual blood flow pattern gets changed. As a result, abnormal sounds are produced with the normal heart beat sound. These abnormal sounds are known as cardiac murmurs. By identifying the murmur type doctors can diagnose the cardiac pathology related to that particular murmur type. This paper describes an electronic stethoscopic device that can be used as a stethoscope as well as murmur identification equipment. Chest piece of an ordinary stethoscope has been used to capture the heart beat with a microphone attached to it. Then the captured signal is amplified and sampled in the device itself and the sampled data is then transmitted to the central location to carry out the signal processing. Since there is a processor inside the device, processing of data can also be done in the device if required. Also the device has the capability of storing the sampled data for future analysis.","PeriodicalId":356868,"journal":{"name":"2011 IEEE International Conference on Industrial Technology","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Industrial Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2011.5754404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

In a healthy heart, there is no any abnormal blood flow takes place inside, in addition to the usual blood circulating pattern. However when the valves or tissues inside the heart are in diseased conditions, this usual blood flow pattern gets changed. As a result, abnormal sounds are produced with the normal heart beat sound. These abnormal sounds are known as cardiac murmurs. By identifying the murmur type doctors can diagnose the cardiac pathology related to that particular murmur type. This paper describes an electronic stethoscopic device that can be used as a stethoscope as well as murmur identification equipment. Chest piece of an ordinary stethoscope has been used to capture the heart beat with a microphone attached to it. Then the captured signal is amplified and sampled in the device itself and the sampled data is then transmitted to the central location to carry out the signal processing. Since there is a processor inside the device, processing of data can also be done in the device if required. Also the device has the capability of storing the sampled data for future analysis.
基于听诊的心脏杂音诊断仪
在健康的心脏中,除了正常的血液循环模式外,内部没有任何异常的血液流动。然而,当心脏内的瓣膜或组织处于病变状态时,这种通常的血流模式就会改变。因此,在正常的心跳声中会产生异常的声音。这些不正常的声音被称为心脏杂音。通过识别杂音类型,医生可以诊断与该杂音类型相关的心脏病理。本文介绍了一种既可作为听诊器又可作为杂音识别设备的电子听诊器。一个普通听诊器的胸部部分被用来捕捉心跳,并与麦克风相连。然后将捕获的信号在设备本身进行放大和采样,然后将采样的数据传输到中心位置进行信号处理。由于设备内部有一个处理器,如果需要,数据处理也可以在设备中完成。该装置还具有存储采样数据以供将来分析的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信