Assessing the Short-term Effects of Endotracheal Intubation on Voice Change and Acoustic Parameters: A Prospective Observational Study

R. Bradoo, A. Joshi, N. Dhorje, Kanchan R. Rupwate, Devika S Arora
{"title":"Assessing the Short-term Effects of Endotracheal Intubation on Voice Change and Acoustic Parameters: A Prospective Observational Study","authors":"R. Bradoo, A. Joshi, N. Dhorje, Kanchan R. Rupwate, Devika S Arora","doi":"10.5005/jp-journals-10023-1191","DOIUrl":null,"url":null,"abstract":"Aims and objectives: (1) To examine vocal symptoms and acoustic changes perceived within 24 hours after endotracheal intubation and (2) to find the association between these changes and endotracheal tube (ET) parameters and determine which parameter affects voice the most. Materials and methods: A prospective analysis of 75 patients was done. They were examined preoperatively, and 2 and 24 hours postoperatively. The vocal symptoms of hoarseness, vocal fatigue, loss of voice, throat clearing (hawking), globus pharyngeus, throat pain, and the acoustic variables mainly average fundamental frequency, shimmer, harmonic noise ratio (HNR), and maximum phonation time (MPT) were assessed. The ET parameters considered were duration of anesthesia, number of attempts at intubation, size of the tube, ET cuff volume, and mean cuff pressure. Results: Approximately 60% of patients with cuff volume above 3 cm 3 and 80% of patients with more than two intubation attempts developed postoperative vocal fatigue, while 70% with mean cuff pressure above 20 cm of water developed postoperative hawking. Conclusion: The ET parameters, mean cuff pressure, and ET cuff volume are the most important variables that are associated with the increase in vocal symptoms. An increase in the value of these parameters is associated with more postoperative discomfort.","PeriodicalId":221737,"journal":{"name":"International Journal of Phonosurgery & Laryngology","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Phonosurgery & Laryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10023-1191","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aims and objectives: (1) To examine vocal symptoms and acoustic changes perceived within 24 hours after endotracheal intubation and (2) to find the association between these changes and endotracheal tube (ET) parameters and determine which parameter affects voice the most. Materials and methods: A prospective analysis of 75 patients was done. They were examined preoperatively, and 2 and 24 hours postoperatively. The vocal symptoms of hoarseness, vocal fatigue, loss of voice, throat clearing (hawking), globus pharyngeus, throat pain, and the acoustic variables mainly average fundamental frequency, shimmer, harmonic noise ratio (HNR), and maximum phonation time (MPT) were assessed. The ET parameters considered were duration of anesthesia, number of attempts at intubation, size of the tube, ET cuff volume, and mean cuff pressure. Results: Approximately 60% of patients with cuff volume above 3 cm 3 and 80% of patients with more than two intubation attempts developed postoperative vocal fatigue, while 70% with mean cuff pressure above 20 cm of water developed postoperative hawking. Conclusion: The ET parameters, mean cuff pressure, and ET cuff volume are the most important variables that are associated with the increase in vocal symptoms. An increase in the value of these parameters is associated with more postoperative discomfort.
评估气管插管对声音变化和声学参数的短期影响:一项前瞻性观察研究
目的和目的:(1)检查气管插管后24小时内的声带症状和声学变化;(2)发现这些变化与气管插管(ET)参数之间的关系,并确定哪个参数对声音影响最大。材料与方法:对75例患者进行前瞻性分析。分别于术前、术后2、24小时进行检查。评估嗓音嘶哑、声带疲劳、失声、清嗓、咽球、咽喉痛等发声症状,以及以平均基频、闪烁、谐波噪声比(HNR)、最大发声时间(MPT)为主的声学变量。考虑的ET参数包括麻醉时间、插管次数、导管大小、ET袖带容积和平均袖带压力。结果:约60%袖带容积大于3cm 3的患者和80%插管次数超过2次的患者术后出现声带疲劳,而70%平均袖带压力大于20cm水的患者术后出现霍金。结论:ET参数、平均袖带压力和ET袖带容积是与声带症状增加相关的最重要变量。这些参数值的增加与术后更多的不适有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信