{"title":"Implementation of quadrature based RMS calculation on real-time power monitoring systems","authors":"S. A. Hussain, F. Zaro, M. A. Abido","doi":"10.1109/PECI.2013.6506060","DOIUrl":null,"url":null,"abstract":"Accurate power system monitoring plays a vital role in detection of supply problems within the supply grid. Of all parameters being monitored, rms based measurements are used to detect various voltage based events within the system. IEEE and IEC based standards utilize full cycle instantaneous samples repeated every half a cycle for the calculation of rms. These measurements are not without limitations especially for short duration variations. This paper proposes 4-instantaneous sample points sampled at 90 degrees apart (quadrature based rms) to estimate rms and further detect voltage events in real-time. The proposed method is experimentally tested and applied for voltage events monitoring using Labview FPGA CompactRio platform. The results demonstrate the effectiveness of the proposed method for estimating the signal rms value with less number of samples.","PeriodicalId":113021,"journal":{"name":"2013 IEEE Power and Energy Conference at Illinois (PECI)","volume":"113 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Power and Energy Conference at Illinois (PECI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECI.2013.6506060","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Accurate power system monitoring plays a vital role in detection of supply problems within the supply grid. Of all parameters being monitored, rms based measurements are used to detect various voltage based events within the system. IEEE and IEC based standards utilize full cycle instantaneous samples repeated every half a cycle for the calculation of rms. These measurements are not without limitations especially for short duration variations. This paper proposes 4-instantaneous sample points sampled at 90 degrees apart (quadrature based rms) to estimate rms and further detect voltage events in real-time. The proposed method is experimentally tested and applied for voltage events monitoring using Labview FPGA CompactRio platform. The results demonstrate the effectiveness of the proposed method for estimating the signal rms value with less number of samples.
基于正交法的均方根计算在电力实时监测系统中的实现
准确的电力系统监测对于发现电网内的供电问题起着至关重要的作用。在所有被监测的参数中,基于有效值的测量用于检测系统内各种基于电压的事件。基于IEEE和IEC的标准利用每半个周期重复的全周期瞬时样本来计算均方根。这些测量并非没有限制,特别是对于短时间的变化。本文提出了以90度间隔采样的4个瞬时采样点(基于正交的均方根)来估计均方根并进一步实时检测电压事件。实验验证了该方法的有效性,并将其应用于Labview FPGA CompactRio平台上的电压事件监测。实验结果表明,该方法能够在较少样本的情况下有效地估计信号均方根值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信