Prototype design of low cost four channels digital electroencephalograph for sleep monitoring

Muhammad Salehuddin, S. Suprijanto, Farida I. Muchtadi
{"title":"Prototype design of low cost four channels digital electroencephalograph for sleep monitoring","authors":"Muhammad Salehuddin, S. Suprijanto, Farida I. Muchtadi","doi":"10.1109/ICA.2011.6130154","DOIUrl":null,"url":null,"abstract":"The electrical activity in brain or known as electroencephalogram (EEG) signal is being used in the diagnosis of sleep quality. Based on EEG signal, power of brain wave that related with a sleep quality could be obtained by analysis of power spectral density. The problem in developing countries, for example in Indonesia, EEG instrument is not widely available in each region of the country. This project designed and implemented four channels digital EEG, in which the design of hardware and software concepts was adopted from OpenEEG project. A four channels EEG amplifier operated by battery with average gain magnitude of 6100 times, bandwidth 0.05–60Hz and slope gradient of −60.00 dB/decade is developed. Digital board consists of AT-mega8 and serial interface with optocoupler is used to interface and viewed EEG signal on notebook. The prototype has successfully detected patterns of cardiac signal simultaneously with good SNR. In EEG measurement through monitoring the brain wave sleep, the data generated by PSD (Power Spectral Density) graph show the dominance of the brain signals at 7–9Hz (alpha) and 3–5Hz (theta). From several tests and measurements, this research concludes that the prototype of low cost EEG 4 channels is capable of acquiring satisfactory brain wave monitoring during sleep from healthy volunteer.","PeriodicalId":132474,"journal":{"name":"2011 2nd International Conference on Instrumentation Control and Automation","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 2nd International Conference on Instrumentation Control and Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICA.2011.6130154","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The electrical activity in brain or known as electroencephalogram (EEG) signal is being used in the diagnosis of sleep quality. Based on EEG signal, power of brain wave that related with a sleep quality could be obtained by analysis of power spectral density. The problem in developing countries, for example in Indonesia, EEG instrument is not widely available in each region of the country. This project designed and implemented four channels digital EEG, in which the design of hardware and software concepts was adopted from OpenEEG project. A four channels EEG amplifier operated by battery with average gain magnitude of 6100 times, bandwidth 0.05–60Hz and slope gradient of −60.00 dB/decade is developed. Digital board consists of AT-mega8 and serial interface with optocoupler is used to interface and viewed EEG signal on notebook. The prototype has successfully detected patterns of cardiac signal simultaneously with good SNR. In EEG measurement through monitoring the brain wave sleep, the data generated by PSD (Power Spectral Density) graph show the dominance of the brain signals at 7–9Hz (alpha) and 3–5Hz (theta). From several tests and measurements, this research concludes that the prototype of low cost EEG 4 channels is capable of acquiring satisfactory brain wave monitoring during sleep from healthy volunteer.
低成本四通道睡眠监测数字脑电图仪的原型设计
脑电活动或称为脑电图(EEG)信号被用于睡眠质量的诊断。以脑电图信号为基础,通过功率谱密度分析得到与睡眠质量相关的脑电波功率。发展中国家的问题是,例如在印度尼西亚,脑电图仪器在该国的每个区域都没有广泛使用。本课题设计并实现了四通道数字脑电图,其中硬件和软件的设计理念均采用OpenEEG项目。研制了一种平均增益为6100倍、带宽为0.05 ~ 60hz、斜率为- 60.00 dB/ 10年的电池供电四通道脑电图放大器。数字板由AT-mega8和串行接口和光耦合器组成,用于在笔记本电脑上接口和查看脑电信号。该样机已成功地同时检测出具有良好信噪比的心脏信号模式。在监测脑波睡眠的脑电图测量中,功率谱密度(PSD)图生成的数据显示7-9Hz (alpha)和3-5Hz (theta)的脑信号占主导地位。通过多次测试和测量,本研究认为低成本的脑电通道原型能够获得健康志愿者睡眠时令人满意的脑电波监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信