{"title":"Power Quality Analysis (0-2kHz) in DC/DC Converters under Steady State and Transient Conditions","authors":"A. Khilnani, K. Niewiadomski, C. Rose, M. Sumner, D. Thomas, E. Ballukja, L. Sandrolini, A. Mariscotti","doi":"10.1109/EMCEUROPE48519.2020.9245758","DOIUrl":null,"url":null,"abstract":"The aim of this paper is to understand the effects of low frequency (0-2kHz) conducted emissions on power quality from a microgrid based DC/DC converter under steady state and transient loading conditions. The experimental data obtained from the lab set-up is analysed using Fast Fourier Transform and low frequency sinusoidal disturbance indices for input DC voltage and current are calculated. The results show that power quality of a DC/DC converter with varying loads does get affected by the conducted emissions, but the indices obtained cannot be quantified due to lack of standards for DC power quality. The indices decrease with increasing load and have a non-zero value at no-load condition. Further, the calculated results from amplitude probability distribution are in agreement with the indices as well.","PeriodicalId":332251,"journal":{"name":"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEUROPE48519.2020.9245758","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this paper is to understand the effects of low frequency (0-2kHz) conducted emissions on power quality from a microgrid based DC/DC converter under steady state and transient loading conditions. The experimental data obtained from the lab set-up is analysed using Fast Fourier Transform and low frequency sinusoidal disturbance indices for input DC voltage and current are calculated. The results show that power quality of a DC/DC converter with varying loads does get affected by the conducted emissions, but the indices obtained cannot be quantified due to lack of standards for DC power quality. The indices decrease with increasing load and have a non-zero value at no-load condition. Further, the calculated results from amplitude probability distribution are in agreement with the indices as well.
稳态和暂态条件下DC/DC变换器(0-2kHz)的电能质量分析
本文的目的是了解在稳态和瞬态负载条件下,低频(0-2kHz)传导辐射对基于微电网的DC/DC变换器电能质量的影响。利用快速傅立叶变换对实验数据进行了分析,并计算了输入直流电压和电流的低频正弦扰动指数。结果表明,不同负载下的DC/DC变换器的电能质量确实会受到传导辐射的影响,但由于缺乏直流电能质量标准,所得到的指标无法量化。这些指标随着负荷的增加而减小,在空载状态下具有非零值。此外,振幅概率分布的计算结果也与指数相吻合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信