A Simple Microwave Gaussian Beam-Launcher for Selective Partial-Body Exposure of Biological Substances

P. Neelakantaswamy, K. Gupta, D. Banerjee
{"title":"A Simple Microwave Gaussian Beam-Launcher for Selective Partial-Body Exposure of Biological Substances","authors":"P. Neelakantaswamy, K. Gupta, D. Banerjee","doi":"10.1109/EUMA.1978.332594","DOIUrl":null,"url":null,"abstract":"A simple and compact gaussian beam launcher to produce a focused microwave field for selective Partial-body exposures in biological experiments is described. The proposed structure consists of a Potter's dual mode horn with slight modifications and the aperture of this hom is loaded with a dielectric sphere (lens). It is shown that the resulting diffracted field in the image-space of the lens is a near-circular gaussian-beam with a high focusing factor. The details of an X-band test launcher with measured and theoretical results are presented. The simplicity of the proposed structure enables a compact and light-weight design of the launcher at the diathermy frequency of 2450 MHz.","PeriodicalId":429268,"journal":{"name":"1978 8th European Microwave Conference","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1978-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1978 8th European Microwave Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMA.1978.332594","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A simple and compact gaussian beam launcher to produce a focused microwave field for selective Partial-body exposures in biological experiments is described. The proposed structure consists of a Potter's dual mode horn with slight modifications and the aperture of this hom is loaded with a dielectric sphere (lens). It is shown that the resulting diffracted field in the image-space of the lens is a near-circular gaussian-beam with a high focusing factor. The details of an X-band test launcher with measured and theoretical results are presented. The simplicity of the proposed structure enables a compact and light-weight design of the launcher at the diathermy frequency of 2450 MHz.
一种用于生物物质选择性局部暴露的简易微波高斯光束发射器
描述了一种简单紧凑的高斯光束发射器,用于产生聚焦微波场,用于生物实验中选择性的部分体暴露。所提出的结构由一个波特双模喇叭稍加修改组成,这个喇叭的孔径上装有一个介电球(透镜)。结果表明,透镜像空间的衍射场为高聚焦系数的近圆形高斯光束。介绍了一种x波段试验发射装置的详细情况,并给出了测量结果和理论结果。所提出的结构的简单性使发射装置在2450 MHz的透热频率下具有紧凑和轻便的设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信