Comparative analysis of LCL filter with active and passive damping methods for grid-interactive inverter system

M. Sowjanya, B. Babu
{"title":"Comparative analysis of LCL filter with active and passive damping methods for grid-interactive inverter system","authors":"M. Sowjanya, B. Babu","doi":"10.1109/TECHSYM.2014.6808074","DOIUrl":null,"url":null,"abstract":"This paper presents the control strategy for a three-phase LCL-filter type based grid connected inverter system for photovoltaic (PV) applications. The control strategy proposed in the paper involves the independent control of active and reactive power injected into the grid during steady state and transient conditions. In addition to that, a comparative study between active and passive damping configurations for LCL type filter resonance damping is also analyzed. The control strategy implemented on a three-phase grid connected PV-inverter is studied and verified by computer simulation based on MATLAB Simulink and the results are analyzed for effectiveness of the study.","PeriodicalId":265072,"journal":{"name":"Proceedings of the 2014 IEEE Students' Technology Symposium","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2014 IEEE Students' Technology Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TECHSYM.2014.6808074","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

This paper presents the control strategy for a three-phase LCL-filter type based grid connected inverter system for photovoltaic (PV) applications. The control strategy proposed in the paper involves the independent control of active and reactive power injected into the grid during steady state and transient conditions. In addition to that, a comparative study between active and passive damping configurations for LCL type filter resonance damping is also analyzed. The control strategy implemented on a three-phase grid connected PV-inverter is studied and verified by computer simulation based on MATLAB Simulink and the results are analyzed for effectiveness of the study.
并网逆变器系统中LCL滤波器主动和被动阻尼的比较分析
提出了一种基于三相lc滤波器型的光伏并网逆变器系统的控制策略。本文提出的控制策略涉及稳态和暂态状态下并网有功和无功的独立控制。此外,还对LCL型滤波器谐振阻尼的主动和被动阻尼配置进行了对比研究。基于MATLAB Simulink对三相并网光伏逆变器的控制策略进行了研究和验证,并对研究结果进行了有效性分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信