Timing jitter measurements at the SLC electron source

J. Sodja, M. Browne, J. Clendenin
{"title":"Timing jitter measurements at the SLC electron source","authors":"J. Sodja, M. Browne, J. Clendenin","doi":"10.1109/PAC.1989.73170","DOIUrl":null,"url":null,"abstract":"The SLC (Stanford Linear Collider) thermionic gun and electron source provide a beam of up to 15*10/sup 10/ e/sup -/ in a single S-band bunch. A 170-keV, 2-ns FWHM (full width at half maximum) pulse out of the gun is compressed by means of two subharmonic buncher cavities followed by an S-band buncher and a standard SLAC (Stanford Linear Accelerator Center) accelerating section. Ceramic gaps in the beam pipe at the output of the gun allow measurement of the beam intensity and timing. A measurement at these gaps of the timing jitter, with a resolution of <10 ps, is described. The timing jitter of the SLC beam at the electron source has a measured upper limit of sigma <or=8.4 ps at the gun output. The timing stability falls well within the stability requirements for injection into the SLC emittance-damping ring.<<ETX>>","PeriodicalId":225182,"journal":{"name":"Proceedings of the 1989 IEEE Particle Accelerator Conference, . 'Accelerator Science and Technology","volume":"396 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1989 IEEE Particle Accelerator Conference, . 'Accelerator Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAC.1989.73170","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The SLC (Stanford Linear Collider) thermionic gun and electron source provide a beam of up to 15*10/sup 10/ e/sup -/ in a single S-band bunch. A 170-keV, 2-ns FWHM (full width at half maximum) pulse out of the gun is compressed by means of two subharmonic buncher cavities followed by an S-band buncher and a standard SLAC (Stanford Linear Accelerator Center) accelerating section. Ceramic gaps in the beam pipe at the output of the gun allow measurement of the beam intensity and timing. A measurement at these gaps of the timing jitter, with a resolution of <10 ps, is described. The timing jitter of the SLC beam at the electron source has a measured upper limit of sigma >
SLC电子源的定时抖动测量
SLC(斯坦福直线对撞机)热离子枪和电子源在单个s波段束中提供高达15*10/sup 10/ e/sup -/的光束。一个170 kev, 2 ns的FWHM(最大宽度的一半)脉冲由两个亚谐波聚束器腔压缩,随后是一个s波段聚束器和一个标准SLAC(斯坦福直线加速器中心)加速部分。在射束管的陶瓷间隙在枪的输出允许测量光束强度和时间。在这些间隙处测量时序抖动,分辨率为>
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信